Download Print this page
Optex OAM-DUAL II Operation Manual

Optex OAM-DUAL II Operation Manual

Advertisement

Quick Links

OAM-DUAL II
Manufacturer's statement
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions that accompany this indication and improper handling
WARNING
may result in serious injury or death.
Failure to follow the instructions that accompany this indication and improper handling
CAUTION
may result in injury and/or damage to property.
NOTE
Pay special attention to sections with this symbol.
NOTE
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic
sliding door. Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment
connected to the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country
in which the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the
building owner/operator on proper operation of the door and the product.
7. The product settings can only be changed by an installer or service engineer.
When changed, the changed settings and the date shall be registered in the maintenance logbook
accompanying the door.
The following conditions are not suitable for sensor installation.
Fog,
Exhaust
Wet
Vibration
Objects
Specifications
Model
: OAM-DUAL II
Cover color
: Black
Mounting height
: 2.0 to 3.5 m (6'7" to 11'6")
Detection area
: See Detection area
Detection method
: Active infrared reflection (*1)
Microwave Doppler effect
Transmitter frequency
: 24.125 GHz
Transmitter radiated power
: < 20 dBm
Depth angle adjustment
: AIR area -6 to +6°
Radar area +25 to +45°
Power supply
: 12 to 24 VAC ±10 % (50/60 Hz)
12 to 30 VDC ±10 %
Power consumption
: < 2.5 W (< 4 VA at AC)
: See Operation indicator table
Operation indicator
Output hold time
: < 1.0 s
Response time
: < 0.3 s
Operation indicator table
Status
Operation indicator color
Warm-up
Stand-by (Installation mode)
Stand-by (Operation mode)
BLUEZONE (Lookback) detection (*2)
2nd row detection
3rd row detection
Radar detection
Signal saturation
Slow Green blinking
Sensitivity too low(or Sensor failure)
Fast Green blinking
NOTE
The specifications herein are subject to change without prior notice due to improvements.
*1 : Active infrared reflection has a presence detection function.
*2 : See BLUEZONE.
BLUEZONE (Lookback) area
When dipswitch 15 is set to "ON", the BLUEZONE (Lookback) area, that provides extra safety over the threshold is
activated. In case the BLUEZONE (Lookback) function is not required, set dipswitch 15 to "OFF".
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.
BLUEZONE
(Lookback)
2nd row
3rd row
Outer dimensions and part names
125(4 15/16")
36(1 7/16")
43(1 11/16")
267(10 1/2")
(2)
(1)
(3)
(4)
(5)
(6)
5928750 NOV 2019
WARNING
Danger of electric shock
Do not wash, disassemble,
rebuild or repair the sensor,
otherwise it may cause electric
shock or breakdown of the
equipment.
Reflection
Operating temperature
: -20 to +55°C (-4 to 131°F)
Operating humidity
: < 80 % (non-condensing)
Noise level
: < 70 dBA
Activation output
: Form C relay 50 V 0.3 A Max.
(Resistance load)
Safety output
: Form C relay 50 V 0.3 A Max.
(Resistance load)
IP rate
: IP54
Weight
: 270 g (9.5 oz)
Accessories
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3 m (9'10")
1 Narrow lens
1 s
Yellow blinking
Yellow
Green
Blue
Red blinking
Red
Orange
BLUEZONE
(Lookback)
2nd row
3rd row
38(1 1/2")
(1) Connector
(2) Mounting holes
(9)
(3) Operation indicator
(4) Width adjustment screws
(5) Depth angle adjustment screw
(6) Radar sensitivity potentiometer
(8)
(7) Dipswitches
(7)
[mm(inch)]
(8) Detection window
(9) Area adjustment tool
ENGLISH
Detection area
A
BLUEZONE(Lookback)
2nd row
3rd row
1.0
(3'3")
2.0
(6'7")
2.0
(6'7")
AIR emitting area
The chart shows the values at depth angle +6°.
A
2.00 (6'7")
2.20 (7'3")
B
0.05 (2")
0.06 (2")
C
0.07 (3")
0.08 (3")
D
0.23 (9")
0.25 (10")
0.39 (1'3")
E
0.35 (1'2")
F
0.59 (1'11")
0.65 (2'2")
G
1.21 (3'12")
1.33 (4'4")
H
1.86 (6'1")
2.05 (6'9")
I
2.52 (8'3")
2.78 (9'1")
NOTE
The actual detection area may become smaller depending on the ambient light, the color/material of
the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
50 mm/s or faster than 1500 mm/s.
Installation
1. Mounting
a. Place the mounting template at the desired mounting position.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
b. Drill two mounting holes of ø3.4 mm (ø1/8").
c. To pass the cable through the header, drill a wiring hole of ø8 mm (ø5/16").
d. Remove the mounting template.
e. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
Header
Sensor
1 s
Y
X
H
Door
Floor
NOTE
Make sure not to mount the sensor lower than the bottom of header.
Make sure to affix the mounting template as described in the above chart, otherwise it can be dangerous since there
may be no detection area around the threshold. Install the sensor as low as possible on the header.
2. Wiring
Wire the cable to the door controller.
Before starting the procedure, make sure that the power is turned OFF. When passing the cable through the hole, do
not tear the shield otherwise it may cause electric shock or breakdown of the sensor.
3. Turn ON the power
a. Plug the connector.
b. Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See Adjustments 4. Dipswitch settings)
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 s in order to enable the presence detection.
4. Mounting the housing cover
Place the housing cover. If wiring is to be exposed, break the knockout.
Knockout
[m(feet,inch)]
Mounting
B
D E
C
G
H
I
1.0
0
1.0
2.0
(3'3")
(3'3")
(6'7")
[m(feet,inch)]
2.50 (8'2")
2.70 (8'10")
3.00 (9'10")
3.50 (11'6")
0.07 (3")
0.07 (3")
0.08 (3")
0.09 (4")
0.09 (4")
0.10 (4")
0.11 (4")
0.12 (5")
0.28 (11")
0.31 (1')
0.34 (1'1")
0.39 (1'3")
0.48 (1'7")
0.61 (2')
0.44 (1'5")
0.53 (1'9")
0.74 (2'5")
0.80 (2'7")
0.89 (2'11")
1.03 (3'5")
1.51 (4'11")
1.63 (5'4")
1.81 (5'11")
2.11 (6'11")
2.32 (7'7")
2.51 (8'3")
2.79 (9'2")
3.25 (10'8")
3.15 (10'4")
3.40 (11'2")
3.79 (12'5")
4.42 (14'6")
H : Height from the floor to the bottom of the header
(The mounting height is "H + Y".)
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
Maximum mounting distance (Y)
H
2.00 (6'7")
2.30 (7'7")
2.50 (8'2")
X
0
0.05 (2")
0.13 (5")
0.13 (5")
0.13 (5")
0.10 (4")
0.11 (4")
0.12 (5")
0.12 (5")
0.15 (6")
0.10 (4")
0.10 (4")
0.11 (4")
0.20 (8")
-
0.09 (4")
0.10 (4")
0.25 (10")
-
-
0.09 (4")
0.30 (12")
-
-
-
CAUTION
Risk of getting caught
Power
1.Grey
1
supply
2.Grey
3.White
Activation
2
4.Yellow
output
5.Green
6.White stripe
Safety
3
7.Yellow stripe
output
8.Green stripe
WARNING
Danger of electric shock
WARNING
Do not use the sensor without the cover. When using the cable knockout,
install the sensor indoors or use the rain cover (Separately available)
otherwise electric shock or breakdown of the sensor may occur.
AIR
Mounting height : 2.2 m (7'3")
Angle adjustment : +6°
Sensitivity : Middle
: Emitting spots
surface
: Emitting spots
(can be eliminated)
: Detection area
F
Radar
Mounting height : 2.2 m (7'3")
Vertical adjustment : +35°
Sensitivity : High
Speed of detection object
: 50 mm/s
: Detection area
(Wide area)
: Detection area
(Narrow area)
[m (feet,inch)]
2.80 (9'2")
3.00 (9'10")
3.50 (11'6")
No limit
0.14 (6")
0.14 (6")
0
0.12 (5")
0.12 (5")
0
0.11 (4")
0.11 (4")
0
0.10 (4")
0.10 (4")
0
0.09 (4")
0.09 (4")
0
-
-
0
12 to 24 VAC ±10 %
12 to 30 VDC ±10 %
COM.
N.O.
N.C.
COM.
N.O.
N.C.
Danger of electric shock

Advertisement

loading

Summary of Contents for Optex OAM-DUAL II

  • Page 1 The sensor may not be activated when the entering speed of the object or a person is slower than 50 mm/s or faster than 1500 mm/s. Model : OAM-DUAL II Operating temperature : -20 to +55°C (-4 to 131°F) Cover color...
  • Page 2 OPTEX hereby declares that the radio equipment type OAM-DUAL series complies with RED 2014/53/EU. Set dipswitch 11 to "ON" when the sensor The full text of the EU DoC is available at the following internet address: www.optex.net operates by itself (Ghosting). When dipswitch Immunity 11 is set to "ON"...