OA-FLEX AIR T
Manufacturer's statement
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions that accompany this indication and improper handling
WARNING
may result in serious injury or death.
Failure to follow the instructions that accompany this indication and improper handling
CAUTION
may result in injury and/or damage to property.
NOTE
Pay special attention to sections with this symbol.
It is required to check the operation manual if this symbol is shown on the product.
NOTE
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic
sliding door. Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment
connected to the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country
in which the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the
building owner/operator on proper operation of the door and the product.
7. The product settings can only be changed by an installer or service engineer.
When changed, the changed settings and the date shall be registered in the maintenance logbook
accompanying the door.
The following conditions are not suitable for sensor installation.
Fog,
Exhaust
Wet
Vibration
Objects
Specifications
Model
: OA-FLEX AIR T
Cover color
: Black
Mounting height
: 2.0 to 3.0 m (6'7" to 9'10")
(2.0m(6'7") to 2.5m (8'2") for
EN16005 compliance)
Detection area
: See Detection area
Detection method
: Active infrared reflection (*1)
Area angle adjustment
: Depth : -8° to +8°
FLEX EYE angle adjustment
: Depth : -14° to +2°
Power supply (*2)
: 12 to 24 VAC ±10 % (50/60 Hz)
12 to 30 VDC ±10 %
Power consumption
: < 2.5 W (< 6 VA at AC)
Operation indicator
: See Operation indicator table
Output hold time
: < 500 ms
Response time
: < 300 ms
Operating temperature
: -20 to +55°C (-4 to 131°F)
Operating humidity
: < 80 %(non-condensing)
Noise level
: < 70 dBA
Operation indicator table
Status
Operation indicator color
Warm-up
Stand-by (Installation mode)
Stand-by (Service mode)
Yellow & Green blinking
Stand-by (Operation mode)
BLUEZONE (Lookback) detection (*4)
2nd row detection
3rd row detection
4th - 6th row detection
FLEX EYE detection
Fast Purple blinking
FLEX EYE & 2nd-4th row detection
Communication Test output
Turn off 500 ms (*5)
Setting error
Red & Green blinking
Signal saturation
Slow Green blinking
Signal saturation (FLEX EYE)
Slow Purple blinking
Sensitivity too low(or Sensor failure)
Fast Green blinking
NOTE
The specifications herein are subject to change without prior notice due to improvements.
*1 : BLUEZONE (Lookback), 2nd and 3rd rows have a presence detection function.
*2 : When using this sensor, the sensor has to be connected to a door system which has the SELV circuit.
*3 : Overcurrent protection with less than 2A.
*4 : See BLUEZONE (Lookback) area
*5 : LED will be turned off approx. 500 ms when the sensor Test output signal works well.
Working principle
This sensor is designed to detect a hand approaching to a touchless plate as a knowing act activation device. Please make
sure to understand the following working principle. If FLEX EYE mode is enabled (Dipswitch 13 is set to "ON"), this sensor
an activation output when both FLEX EYE and 2nd to 4th row of detection area detect some objects.
FLEX EYE means an area for the hand detection.
FLEX EYE
FLEX EYE
6
5
4
3
2
1
6
NOTE
Safety output is designed to be used on door system that enables only while the door is open.
BLUEZONE is only activated while Activation output is emitted. When no detection, BLUEZONE is
deactivated. When FLEX EYE is enabled (Dipswitch 13 is set to "ON"), detection area (of 2nd to 6th row)
is safety output area.
BLUEZONE (Lookback) area
When dipswitch 15 is set to "ON", the BLUEZONE (Lookback) area, that provides extra safety over the threshold is
activated. In case the BLUEZONE (Lookback) function is not required, set dipswitch 15 to "OFF".
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.
4th row
3rd row
5th row
2nd row
BLUEZONE
6th row
(Lookback)
5930280 JAN 2021
Original instructions
WARNING
Danger of electric shock
Do not wash, disassemble,
rebuild or repair the sensor,
otherwise it may cause electric
shock or breakdown of the
equipment.
Reflection
Activation output
: Form A relay 50 V 0.3 A Max.
(Resistance load)
Safety output
: Form A relay 50 V 0.3 A Max.
Test input
: Opto coupler
Voltage 5 to 30 VDC
Current 6 mA Max. (30 VDC)
IP rate
: IP54
Width : ±7°
Category
: 2 (EN ISO 13849-1:2015)
Width : ±42°
Performance level
: d (EN ISO 13849-1:2015)
ESPE
: Type 2
Weight
: 230 g (8.1 oz)
Accessories
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3 m (9'10")(*3)
1000 ms
Yellow blinking
Yellow
Green
Blue
Red blinking
Red
Orange
Purple
BLUEZONE
BLUEZONE
FLEX EYE
5
4
3
2
1
6
5
4
4th row
3rd row
5th row
2nd row
6th row
BLUEZONE
(Lookback)
2nd row overlapping
the threshold
Complied standards and extract from EC declaration of conformity
ENGLISH
DIN 18650-1:2010 Chapter 5.7.4 ESPE
EN 16005:2012/AC:2015 Chapter 4.6.8 and Annex C
EN 61000-6-2:2005/AC:2005
EN 61000-6-3:2007 +A1:2011/AC:2012
EMC Directive 2014/30/EU
Machinery Directive 2006/42/EC
Notified Body 0044 : TÜV NORD CERT GmbH Langemarckstr. 20 45141 Essen Germany
For technical document, see European Subsidiary
NI-0181-1
Outer dimensions and part names
245(9 5/8")
36(1 7/16")
(1)
(3)
(4)
Detection area
Charts show the values in the following area angle adjustment settings.
Depth : 8°
Width : 0°
BLUEZONE
(Lookback)
2nd row
3rd row
4th row
5th row
6th row
Detection area
To comply with EN 16005, make sure that the detection area is within the values of the chart below.
A
2.00 (6'7")
X
0.24 (9")
H
0.85 (2'9")
J
2.01 (6'7")
The values above are those of the Detection area when tested referring to the test conditions of EN 16005.
(The emitting area is as shown in Emitting area above.)
NOTE
The actual detection area may become smaller depending on the ambient light, the color/material of the
object or the floor as well as the entry speed of the object. The sensor may not be activated when the
entering speed of the object or a person is slower than 50 mm/s or faster than 1500 mm/s.
Installation
1. Mounting
1000 ms
a. Place the mounting template at the desired mounting position.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
b. Drill two mounting holes of ø3.4 mm (ø1/8").
c. To pass the cable through the header, drill a wiring hole of ø8 mm (ø5/16").
d. Remove the mounting template.
e. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
Header
Sensor
Y
X
H
Door
Floor
NOTE
Make sure not to mount the sensor lower than the bottom of header.
2. Wiring
Wire the cable to the door controller.
* The following 2 cables are not used.
Grey/Pink
Red/Blue
** See DIP 8(Test input) comment
in "4. Dipswitch settings".
WARNING
Danger of electric shock
Before starting the procedure, make
sure that the power is turned OFF.
When passing the cable through the
3
2
1
hole, do not tear the shield otherwise it
may cause electric shock or breakdown
of the sensor.
3. Turn ON the power
a. Plug the connector.
b. Supply power to the sensor. Adjust the detection area and set the dipswitches.(See Adjustments 4. Dipswitch settings)
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 s in order to enable the presence detection. Do not touch the dipswitches before turning the
power ON, otherwise an error occurs. After changing the dipswitch settings, make sure to push the
function switch for 2 s.
4. Mounting the housing cover
Place the housing cover.
If wiring is to be exposed, break the knockout.
37(1 7/16")
125(4 15/16")
43(1 11/16")
(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Function switch
(2)
[mm (inch)]
(5) FLEX EYE Width angle adjustment screw
(6) FLEX EYE Depth angle adjustment screw
(7) Dipswitches
(8) Area angle adjustment screws
(9) Area width adjustment screws
(10) Detection window
(5) (6)
(7)
(8)
(9)
(10)
(11)
(11) Area adjustment tool
Emitting area
FLEX EYE
A
B
C
D
X
E
F
G
H
I
: Emitting spots
J
[m(feet,inch)]
2.30 (7'7")
2.50 (8'2")
Test conditions required by EN 16005
Floor : Grey paper
0.25 (10")
0.23 (9")
Detection object : EN 16005 CA reference body
0.91 (2'12")
0.96 (3'2")
Sensitivity : High
Speed of detection object : 50 mm/s
2.20 (7'3")
2.44 (8')
H : Height from the floor to the bottom of the header
(The mounting height is "H + Y".)
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
Maximum mounting distance (Y)
[m (feet,inch)]
H
2.00 (6'7")
2.30 (7'7")
2.50 (8'2")
X
0
0.14 (6")
0.14 (6")
0.14 (6")
0.05 (2")
0.13 (5")
0.13 (5")
0.13 (5")
0.10 (4")
0.11 (4")
0.11 (4")
0.11 (4")
0.15 (6")
0.10 (4")
0.10 (4")
0.10 (4")
0.20 (8")
0.09 (4")
0.09 (4")
0.09 (4")
0.25 (10")
0.07 (3")
0.07 (3")
0.07 (3")
0.30 (12")
0.06 (2")
0.06 (2")
0.06 (2")
Power supply
Activation output 2
Safety output
Test input **
Not used *
1
12 to 24 VAC ±10 % / 12 to 30 VDC ±10 %
2
Form A relay 50 V 0.3 A Max.
3
Form A relay 50 V 0.3 A Max.
4
Opto coupler / Voltage: 5 to 30 VDC
WARNING
Do not use the sensor without the cover. When using the cable knockout,
install the sensor indoors or use the rain cover (Separately available)
otherwise electric shock or breakdown of the sensor may occur.
EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3
EN 12978:2003 +A1:2009
EN ISO 13849-1:2015
EN ISO 13849-2:2012
A. Maekawa
General Manager
OPTEX CO., LTD.
Quality Control Dept.
Touchless plate
ø83 (ø3 4/16")
[m(feet,inch)]
A
2.00 (6'7")
2.30 (7'7")
2.50 (8'2")
B
0.13 (5")
0.16 (6")
0.17 (7")
C
0.38 (1'3")
0.46 (1'6")
0.50 (1'8")
D
0.71 (2'4")
0.86 (2'10")
0.94 (3'1")
E
0.84 (2'9")
1.01 (3'4")
1.09 (3'7")
F
1.34 (4'5")
1.62 (5'4")
1.76 (5'9")
G
1.75 (5'9")
2.11 (6'11")
2.29 (7'6")
H
0.92 (3')
1.11 (3'8")
1.20 (3'11")
I
1.49 (4'11")
1.80 (5'11")
1.95 (6'5")
J
2.06 (6'9")
2.48 (8'2")
2.69 (8'10")
: Emitting spots
: Detection area
(can be eliminated)
CAUTION
Risk of getting caught
Make sure to affix the mounting
template as described in the
above chart, otherwise it can be
dangerous since there may be
no detection area around the
threshold. Install the sensor as
low as possible on the header.
1.White
1
2.Brown
3.Green
4.Yellow
Polarity free
5.Pink
3
6.Blue
7.Red
4
8.Black
9. Grey/Pink
10. Red/Blue
Danger of electric shock

Advertisement

loading

Summary of Contents for Optex OA-FLEX AIR T

  • Page 1 (can be eliminated) Detection area Model : OA-FLEX AIR T Activation output : Form A relay 50 V 0.3 A Max. To comply with EN 16005, make sure that the detection area is within the values of the chart below.
  • Page 2 * After changing the dipswitch settings, make sure to push the function switch for 2 s. Select the FLEX EYE mode "ON" or "OFF". Manufacturer EMEA Subsidiary ON : Activation output is emitted when a OPTEX CO., LTD. OPTEX Technologies B.V. FLEX EYE detection occurs in FLEX EYE and the 2nd to mode 4th row.