Fill Up Fuel Tank; Connecting The High Pressure Hose - Nilfisk-Advance MH 5M Instructions For Use Manual

Hide thumbs Also See for MH 5M:
Table of Contents

Advertisement

3.7

Fill up fuel tank

3.8
Connecting the high
pressure hose
3.8.1 Machines with high
pressure hose reel
3.8.2 Machines without high
pressure hose reel
8
NOTE!
The fuel must be free from con-
tamination.
Tank capacity see chapter 9.4
Technical data.
NOTE!
At temperatures below 8°C
(46°F), the fuel oil begins to so-
lidify (paraffi n precipitation). This
can lead to diffi culties in starting
1)
A
With the machine cold, turned
off and disconnected from power
supply:
1. Fill fuel tank from a clean con-
tainer with a fresh fuel, heat-
ing oil, DIN 51603-1 (without
bio diesel) or Diesel EN 590
(Diesel with a bio diesel con-
tent up to 7%).
Diesel according to EN 590
(up to 7% bio diesel) can be
used with the following re-
strictions: Maximum storage
time in high pressure cleaner
diesel tank: 1 month. Diesel
stored externally for more
than 6 months is not allowed
to be fi lled into Nilfi sk high
pressure cleaners. Diesel
EN 590 is not recommended
for use in HPW's at an ambi-
ent temperature below 0°C.
Diesel EN 590 from an open
container must not be used.
the burner. Before the winter
months it is recommended that
a fuel conditioner/stabilizer be
added (available from the fuel
oil trade).
1. Connect the high pressure
B
hose quick connector to the
high pressure nipple (A) lo-
cated at the hose reel axle.
C
2. Place the high pressure hose
into the hose guide (B) and
ritain it with the clip.
3. Release the brake (C) on the
hose reel and wind up the
high pressure hose.
1. Connect the high pressure
hose quick connector to the
high pressure nipple located
at right rear of machine above
chemical tank.
Options / model variants
1)
Original instructions

Hide quick links:

Advertisement

Table of Contents
loading