Mitsubishi Electric MELSECSystem Q User Manual page 90

Q64tctt;q64tcttbw; q64tcrt;q64tcrtbw
Table of Contents

Advertisement

5 UTILITY PACKAGE (GX Configurator-TC)
Function
Monitors and tests the buffer memory and I/O signals for the temperature control module.
you can use the auto tuning function.
•Write Data Error Code
•CH
•CH
•CH
•CH
•CH
•CH
•X00:Module Ready Flag
•X01:Setting/Operation Mode Status
•X02:Write Error Flag
•X03:Hardware Error Flag
•X04:CH1 Auto Tuning Status
•X05:CH2 Auto Tuning Status
•X06:CH3 Auto Tuning Status
•X07:CH4 Auto Tuning Status
•X08:E
•X09: Default Value Write Completion Flag
•X0A:E
•X0B:Setting Change Completion Flag
•X0C:CH1 Warning Occurred Flag
•X0D:CH2 Warning Occurred Flag
•X0E:CH3 Warning Occurred Flag
•X0F:CH4 Warning Occurred Flag
•Y01:Setting/Operation Mode Instruction
•Y02:Error Reset Instruction
Monitor/test
•Y04:CH1 Auto Tuning Instruction
•Y05:CH2 Auto Tuning Instruction
•Y06:CH3 Auto Tuning Instruction
•Y07:CH4 Auto Tuning Instruction
•Y08:E
•Y09:Default Setting Registry Instruction
•Y0B:Setting Change Instruction
•Y0C:CH1 PID Calculation Compulsory
•Y0D:CH2 PID Calculation Compulsory
•Y0E:CH3 PID Calculation Compulsory
•Y0F:CH4 PID Calculation Compulsory
•CH
•CH
•CH
•CH
•CH
Completion Flag
•CH
•CH
•CH
•PID Continue Flag
•CH
•PID Continue Flag
•CH
Cross Warning
•CH
Cross Warning
5 - 2
Description
Decimal Point Place
Measured Temperature Value(PV)
Operation Level(MV)
Target Value Setting(SV)
Transistor Output Flag
ON Delay Output
2
PROM Write Completion Flag
2
PROM Write Fail Flag
2
PROM Backup Instruction
Proportion(P) Setting
Integral Time(I) Setting
Differential Time(D) Setting
2
E
PROM PID Constant Read Instruction
2
E
PROM PID Constant Read
Output Control Cycle Setting
Control Response Parameter
Stop Mode Setting
Stop Mode Setting
Temperature Value (PV) Upper Limit
Temperature Value (PV) Lower Limit
•CH
Warning1
•CH
Warning2
•CH
Warning3
•CH
Warning4
•CH
Heater Down Warning
•CH
Loop Down Warning
•CH
OFF Time Abnormal Current Warning
•CH
Warning1 Mode Setting
•CH
Warning Setting Value1
•CH
Warning2 Mode Setting
•CH
Warning Setting Value2
•CH
Warning3 Mode Setting
•CH
Warning Setting Value3
•CH
Warning4 Mode Setting
•CH
Warning Setting Value4
•Warning Non Sensitive Zone Setting
•Warning Delay Count
•CH
Loop Down Detect Decision Time
•CH
Loop Down Detect Dead Band
•CH
Heater Down Warning
•Heater Down/OFF Time Abnormal Current
Detect Delay Count
•Heater Down Correction Function Select
•CT Monitor Format Change
•CT
Measured Heater Current Value
•CT
Channel Layout Setting
•CT
CT Select
•CT
Standard Heater Current Value
•CH
Operation Level
•Operation Level Resolution Change
•CH
Temperature Rise Decision Flag
•Temperature Rise Complete Range Setting
•Temperature Rise Complete Sock Time Setting
•CH
Input Range
•CH
Upper Limit Setting Limiter
•CH
Lower Limit Setting Limiter
•CH
Forward/Reverse Operation Setting
•CH
Change Rate Limiter Setting
•CH
Sensor Correction Value Setting
•CH
Temporary Delay Digital Filter Setting
•CH
Upper Limit Output Limiter
•CH
Lower Limit Output Limiter
•CH
Output Change Level Limiter
•CH
Sensor Adjustment(NonSensitive)
•CH
AT Bias
•CH
Unused Channel Setting
•Transistor ON Time Output Delay Monitor Setting
•CH
MAN Mode Switch Completion Flag
•CH
AUTO/MAN Mode Change
•CH
MAN Output Setting
•Auto Tuning
MELSEC-Q
Reference
section
5
Section 5.6
5 - 2