Connection

Figure 5-11 Connection Configuration Interface

Table 5-9 Connection Configurations

Parameter
Max
Connection
TCP Port
UDP Port
HTTP Port
RTSP Port
HTTPS
HTTPS Port
Function
Displays the maximum number of network connections for the same camera. The
value ranges from 1 to 20. The maximum number of connections is 20.
The default setting is 37777. You can modify this setting as necessary.
The default setting is 37778. You can modify this setting as necessary.
The default setting is 80. You can modify this setting as necessary.
The default setting is 554. The RTSP stream query format is:
Main stream:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=0
Sub stream:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=1
You are required to manually enter the following four items: Username,
Password, IP, and Port.
IP: The camera's IP address.
Port: The default is 554. You can leave this field blank if you are using the default
value.
Follow standard RTP protocols. When the encode mode is MJPEG, the maximum
supported resolution is 2040×2040.
HTTPS is enabled by default. To disable HTTPS, clear the check box.
The default setting is 443.