Onboard low-profile PCI expansion slot cover

CAUTION:
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
CAUTION:
all bays are populated with either a component or a blank.
To remove the component:
Power down the server (on page 26).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 27).
o
Remove the server from the rack (on page 29).
o
Remove the access panel
4.
Remove the onboard PCI expansion slot cover.
5.
To replace the component, reverse the removal procedure.

Primary PCI riser cage

The primary PCIe riser location in this server supports either a GPU riser cage or a two-slot PCI riser cage.
WARNING:
internal system components to cool before touching them.
To prevent damage to electrical components, take the appropriate anti-static
To prevent improper cooling and thermal damage, do not operate the server unless
("Access
panel" on page 34).
To reduce the risk of personal injury from hot surfaces, allow the drives and the
Removal and replacement procedures 58

Advertisement

Table of Contents
loading

Table of Contents