Hot-plug drive
CAUTION:
all bays are populated with either a component or a blank.
To remove the component:
Back up all server data on the drive.
1.
If installed, remove the security bezel
2.
Determine the status of the drive from the drive LED definitions
3.
101).
Remove the hot-plug drive.
4.
To replace the component, reverse the removal procedure.
Access panel
WARNING:
internal system components to cool before touching them.
CAUTION:
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
CAUTION:
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
To remove the component:
Power down the server (on page 26).
1.
If you are performing a non-hot-plug procedure, remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 27).
o
Remove the server from the rack (on page 29).
o
If the locking latch is locked, use a T-15 Torx screwdriver to unlock the latch.
4.
To prevent improper cooling and thermal damage, do not operate the server unless
("Remove the security bezel
To reduce the risk of personal injury from hot surfaces, allow the drives and the
To prevent damage to electrical components, take the appropriate anti-static
Do not operate the server for long periods with the access panel open or removed.
(optional)" on page 26).
("HP SmartDrive LED
definitions" on page
Removal and replacement procedures 34