TEMPGAP=7F (or TEMPGAP=4C). In this case, the thermostat will operate in heating
mode with less switching and will maintain the temperature in the region of 75F-82F
(24C-28C). The heater will be activated at 75F (24C) and will be turned off at 82F
(28C). The next time the heating will only be activated when the temperature falls to
75F (24C).
NOTE! You save energy when there are no abrupt changes of the temperature or frequent
changes beyond the specified range on the controlled site. The value of TEMPGAP must be
calculated individually for each individual case.
Useful note. When you configure the thermostat you usually need to execute 4 SMS
commands or less. You may use Multi Texting Mode to execute them in one message –
see Chapter 4.4. for details.
iSocket Smart Thermostat also supports the configuration of so-called profiles through a
scheduler – you may change the SWITCHOFFTEMP setting at a particular time of day.
Please see details in Chapter 10.
Command
THERMOSTATON
THERMOSTATOFF
THERMOSTAT=
HEATING
THERMOSTAT=
COOLING
SWITCHOFFTEMP=10C
or
SWITCHOFFTEMP=50F
THERMOSTAT?
TEMPGAP=5F
or
TEMPGAP=3C
Do you particularly agree, or disagree with anything in our software?
© Copyright iSocket Systems 2017
All rights reserved. Version 1.0.2-EN
Description
Activate thermostat
Disables thermostat. Please
note, disabling of the thermostat
will not change the relay status.
Set the condition of thermostat.
Use this value if heating system
is connected to device
Set the condition of thermostat.
Use this value if cooling system
is connected to device
Set the temperature for turning
off the main socket when
thermostat enabled. Values
from -67F to 248F, or from -
55C to 120C. Do not forget to
type F (means Fahrenheits) or
C (means Celsius) after the
value. Only integer values must
be used!
Information about thermostat
configuration
Sets the deviation for the
thermostat – see description
above in this Chapter. Values
from 1F to 30F or from 1C to
20C. It is set to 2F (1C) by
default.
Give us your opinion: http://isocket.me/feedback
Response
Thermostat function is working
now.
Mode: Heating
Switch-off temperature: 50F (10C)
Thermostat function was disabled!
The relay remains in the same
status.
THERMOSTAT=HEATING – OK
Switch-off temperature: 50F (10C)
Thermostat: Enabled
THERMOSTAT=COOLING – OK
Switch-off temperature: 72F (22C)
Thermostat function: Enabled
SWITCHOFFTEMP=50F (10C) – OK
Mode: Cooling
Thermostat function: Disabled
Thermostat function: Disabled
Mode: Cooling
Switch-off temperature: 50F (10C)
TEMPGAP=5F (3C) - OK
- 18 -
www.isocket3g.com
Type
Ctrl
Ctrl
Conf
Conf
Conf
Inf
Conf
English