Measurement And Control Of Temperature - iSocket 3G User Manual

Table of Contents

Advertisement

iSocket
®
3G
you can then disable the error message responses. In the beginning however, we strongly
recommend configuring the list of allowed numbers (Chapter 5.1) and keeping the option
SMSCONFIRMUNAUTH, which is set to OFF by default.
Command
ERROR=ON
ERROR=OFF
ERROR?
SMSCONFIRMUNAUTH=ON
SMSCONFIRMUNAUTH=OFF
SMSCONFIRMUNAUTH?

7. Measurement and Control of Temperature

iSocket 3G supports one external digital temperature sensor that can measure the
temperature of different elements (air, liquid, solid, etc) from -67F (-55C) to 248F (120C)
with an accuracy of ±0.5˚C. You can buy sensors with different lengths of cable from us.
The sensor must be connected to the RED 3.5mm jack socket on the rear of device.
Sensor with long cable, e.g. 10ft (3m). This sensor can
be a good option to measure the temperature outside.
The probe is weatherproof and has a "wingnut" for
screwing. This sensor is also a good option if iSocket is
located close to the heating system, which may affect
temperature measurements. Long cable will allow you to
install the sensor far from the source of heating, and then
you can measure the temperature at precisely the point
you want: e.g. ceiling, floor or in the middle of room.
(Model: ITS30J). This sensor can be used for measuring
the temperature of water, but this is not recommended –
please consider Temperature Sensor Pro for these
purposes. For heavy-duty conditions such as a fish tank
with salt water or a boiler that heats up to 212F (100C),
or oil, the Temperature Sensor Pro with IP68 protection
class will be the best solution. (Model: ITS30JPRO).
IMPORTANT NOTE! Do not insert or remove the temperature sensor on a running
device! Switch off the device before you insert or remove the temperature sensor.
Do NOT apply excessive force! – This will damage the jack!
© Copyright iSocket Systems 2017
All rights reserved. Version 1.0.2-EN
Description
Activates sending of information SMS
for each received SMS command,
which was not executed due to any
error.
Disable the error messages responses
Information about ERROR configuration
Send reports (errors, not permitted,
time out) to unauthorized numbers
Don't send reports to unauthorized
numbers
Information about
SMSCONFIRMUNAUTH configuration
- 15 -
www.isocket3g.com
Response
ERROR=ON - OK
ERROR=OFF - OK
ERROR =(ON),OFF
SMSCONFIRMUNAUTH
=ON – OK
SMSCONFIRMUNAUTH
=OFF – OK
SMSCONFIRMUNAUTH
=(OFF),ON
Short
sensor
to
temperature near a device. Can
be a good option if you want to
monitor the temperature just
inside
a
room.
cables. (Model: ITS00J).
Type
Conf
Conf
Inf
Conf
Conf
Inf
measure
No
messy
English

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3G and is the answer not in the manual?

Table of Contents