iSocket
®
3G
3. Control and management commands (marked "Ctrl" in the tables).
Used to control the iSocket device - perform some active action. They are not limited by
configuration window and can be used at any time.
You will get a response after sending the commands. This can be disabled if desired (see
Chapter 6). If you make a mistake in the command and send an incorrect command, you
will receive a message "COMMAND - No such command exists on the device!" (Only if
ERROR=ON - see Chapter 6). If a command longer than 30 characters was sent, it will be
deleted without any response notifications.
The list of simple commands for management and configuration is shown in the following
table. The real response may differ from those indicated in the table, depending on the
command. For default settings please see Chapter 13.
Command
Description
ON
Turn on main power socket
OFF
Turn off main power socket
ON30
Turn on main power socket for 30 seconds.
Maximum value is 65500 seconds.
OFF30
Turn off main power socket for 30 seconds.
Maximum value is 65500 seconds.
RESTART
Restart (return to the same status after a certain
period of time) main socket. Time for restart set
by RESTARTTIME.
RESTARTTIME=5 Configures time (in seconds) for RESTART
command. Values 1-600 seconds.
RESTARTTIME?
Informs about RESTARTTIME value
PULSE
Send a pulse to relay. The duration of the pulse
can be configured by command PULSETIME. By
default this is 2 seconds. This operation works
similarly to the RESTART operation. So, if main
socket was turned off it will be turned on for a 2
seconds and then turned off. And if the socket
was initially turned on, then after this action it
will be turned off for 2 seconds and then turned
on again. So this pulse can be used as a
pushbutton to start and stop, for example,
magnetic starters or to open a gate. Values 1-
600 seconds.
PULSETIME=2
Configures time (in seconds) for PULSE
command. Values 1-600 seconds.
PULSETIME?
Informs about PULSETIME value
STATUS
Request for main power socket status,
temperature, network and time
TEMPERATURE
Informs about temperature. See details in
Chapter 7.
RUNTIME
Informs how long main power socket has been
turned on (since last restart or power on). If you
turn on the main socket manually before the
correct date was installed on the device, the
start-up time of the device will not be
recorded correctly.
4.2 Managing by Phone Call
The main socket for external electrical equipment can also be managed by cell or landline
phone. For example, you can call to the phone number of the SIM card in the device and
© Copyright iSocket Systems 2017
All rights reserved. Version 1.0.2-EN
- 9 -
www.isocket3g.com
Response
Power socket ON
Power socket OFF
Power ON for 30 seconds
Power OFF for 30 seconds
Power socket restarted
RESTARTTIME=5 – OK
RESTARTTIME=5 seconds
Pulse on/off for 2 seconds
was sent to relay
Pulse off/on for 4 seconds
was sent to relay
PULSETIME=2 – OK
PULSETIME=2 seconds
Power socket ON
Signal: Good(-67dBm),
HSDPA
TEMP: 70F (21C)
Time: y/m/d,h:m:s
TEMPERATURE: 70F (21C) Ctrl
Power socket is ON from:
y/m/d,h:m:s
Type
Ctrl
Ctrl
Ctrl
Ctrl
Ctrl
Conf
Inf
Ctrl
Conf
Inf
Ctrl
Ctrl
English