Section 4: Specifications

October 2016
Section 4: Specifications
Maximum Inlet Pressure 56-21XX Series: 15,000 psig / 1034 bar
Maximum Inlet Pressure 56-22XX Series: 10,000 psig / 690 bar
Maximum Outlet Pressure 56-21XX Series: 14,800 psig / 1034 bar
Maximum Outlet Pressure 56-22XX Series: 4000 psig / 276 bar
Operating Temperature (All):
Weight 56-21XX Series:
Weight 56-22XX Series:

Section 5: Drawings

5 .1

Installation Diagram for 56-21XX Series

Letter call-outs are referenced in the Installation and Start-Up Procedures section
of this manual.
F
C
INLET
INLET
BLOCK
VALVE
8
D
15,000
psig
56-21XX Series Assembly
56-21XX and 56-22XX Series
0 to 165°F / -18 to 73°C
Approximately 18.26 lbs / 8.28 kg
Approximately 9.09 lbs / 4.12 kg
G
B
6,000
psig
E
DOPSM2097X012
A
OUTLET
OUTLET
BLOCK