Specifications; Electrical Installation - Tescom ER1200 Series Operation & Service Manual

Closed loop pressure control system
Table of Contents

Advertisement

SPECIFICATIONS

Enclosure
NEMA 4 housing
Mounting
2 10-32 UNF mounting holes
Power Requirement
24 Volts DC +/- 2 volts
150 milliAmp typical current draw
Input Signals
All signals are field configurable using
onboard jumpers:
Setpoint:
4-20 mAmp, 1-5 VDC or
0-10 VDC
Feedback: Internal (0-100 PSIG) or
external
External
Feedback: 4-20 mAmp, 1-5 VDC or
0-10 VDC

ELECTRICAL INSTALLATION

Wire Number
1
2
3
4
5
6
7
8
Form # 1925
Rev. 4/06
TESCOM
Inlet Pressure
Media
Environment
Flow Stream Materials
Performance
Wire Color
White
Brown
Green
Yellow
Black
Red
Orange
Violet*
3
Maximum: 120 PSIG
Typical:
110 PSIG
Minimum: 10 PSIG above desired
output pressure
Clean, dry, inert gas
Temperature: -10°F to +150°F
300 Series SST, Buna-N, 6000 Series
Aluminum, Brass, Nickel, Silicon, Gold,
Glass, RTV
Total Accuracy: +/- 0.25%
Linearity:
+/- 0.1%
Repeatability:
+/- 0.12%
Flow Capacity: C v = 0.03
Function
+ Setpoint
- Setpoint
+ Feedback
+ Analog Output
Power Ground
+ TTL Output
+ 24 VDC Power
Secondary Ground
*
Not available for ER1200-2 and ER1200-2-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Er1200-1-1Er1200-1Er1200-2Er1200-2-1

Table of Contents