4.5.8 Digital Outputs
The ER3000's can provide digital outputs to the rest of the system. The outputs
can be toggled using a PC computer program or as part of a pressure profile.
This can be used to trigger a process in another part of the system or simply turn
on a light bulb or sound an alarm.
This feature is only available on ER3000 models that have the digital outputs, as
referenced in Section 3 (ER3000 Model Description).
Figure 17: ER3000 Digital Outputs
Output load #1 is shown in Figure 17 using an external supply to switch a
12VDC solid state relay, which controls the load.
Output load #2 is shown in Figure 17 using the ER3000's power supply to
switch a 24VDC relay, which controls the load.
26 ER3000 User Manual