Er3000 Part Numbering System - Tescom ER3000 User Manual

Electronic pressure controller
Hide thumbs Also See for ER3000:
Table of Contents

Advertisement

3. ER3000 PART NUMBERING SYSTEM

Standard features:
RS485 communications included.
1/8" inlet and exhaust ports, 1/4" controlled output port.
Maximum inlet pressure = 120 psig.
0 to 100 psig internal sensor.
Windows/DOS software package included.
24 VDC power required.
As the table below indicates, other sensor ranges are available. Please consult
the factory for special modifications or requirements.
Base Style
00...Standard
02...Integrated with
26-1000 and 269-529
04...OEM style (no
cover)
10...Integrated with
44-4000
11...Integrated with
44-5200
10 ER3000 User Manual
ER3 XX X X X - X
Internal Sensor Configuration
0...0-100 psig, 0.1% accuracy
2...0-50 psia, 0.1% accuracy
3...0-150 psia, 0.1% accuracy
4 0-5 psig, 0.25% accuracy
Current/Voltage
I...4-20 mA/1-5 VDC
V...0-10 VDC
Board Configuration
S...Standard
(setpoint/feedback)
F...2 extra analog
inputs/outputs
E...Explosion proof
G...Combines F & E
M...KEMA explosion proof
N...Combines F & M
Cv
Configuration
1...Standard,
Cv=0.01
2...Low flow
(Cv=0.001)
4...High flow
(Cv=0.1)

Advertisement

Table of Contents
loading

Table of Contents