7)
CLEANING FUNCTION (RELAY D)
*
Action: Disable/Manual Clean/Auto+Manual Clean
Auto Clean:
Time repetition: 0.1/24.0 h
*
Cleaning time: 0.5/60.0"
*
Hold time: 0.1'/20.0'
Relay contacts: SPST
8)
ANALOG OUTPUT Nr. 1
* Current range: 0-20/4-20 mA
* Point 1 corresponding to 0 mA or 4 mA
RANGE 20.00 PPM: 0.00/20.00
RANGE 2.000 PPM: 0.000/2.000
TEMPERATURE: 0.0°C/50.0°C (Option 091.3711)
* Point 2 corresponding to 20 mA
RANGE 20.00 PPM: 0.00/20.00
RANGE 2.000 PPM: 0.000/2.000
TEMPERATURE: 0.0°C/50.0°C (Option 091.3711)
Response time: 10 s for 98 %
Isolation: 250 Vca
Rmax: 600 Ω
9)
ANALOG OUTPUT N°2 (only for Option 091.3711)
*
Current range: 0-20/4-20 mA
*
Point 1 corresponding to 0 mA or 4 mA
RANGE 20.00 PPM: 0.00/20.00
RANGE 2.000 PPM: 0.000/2.000
TEMPERATURE: 0.0 °C/50.0 °C
* Point 2 corresponding to 20 mA
RANGE 20.00 PPM: 0.00/20.00
RANGE 2.000 PPM: 0.000/2.000
TEMPERATURE: 0.0 °C/50.0 °C
Response time: 10 s for 98 %
Isolation: 250 Vca
Rmax: 600 Ω
Operator's Manual - Rev. C - 05/05
CL 7685
|
|
| Disable
|
|
| 24.0 h
| 15.0"
| 3.0'
|
|
|
|
| 0/20 mA
|
| 0.00 PPM
| 0.000 PPM
| 0.0 °C
|
| 20.0 PPM
| 2.000 PPM
| 50.0 °C
|
|
|
|
|
| 0/20 mA
|
| 0.00 PPM
| 0.000 PPM
| 0.0 °C
|
| 20.00 PPM
| 2.000 PPM
| 50.0 °C
|
|
|
-