3.2.4
Parameter copy (PRCpy set)
(1) Copying parameter settings
Parameter settings of an inverter can be read, and the settings of maximum three inverters can be stored in the FR-LU08. The
stored parameter settings can be copied to other same-series inverters.
• Reading the parameter settings of the inverter and storing them to the FR-LU08
Connect the FR-LU08 to the inverter that contains the
1
parameters to be copied.
Display the function menu, turn
2
[PRCpy set], and press
(SET)
Turn
to move the cursor
to the copy area used, and
3
press
.
(SET)
Turn
to move the cursor
to [1: Read VFD], and press
4
.
(SET)
26
MENU
to move the cursor to
.
PRCpy set
Copyarea1
Copyarea2
Copyarea3
STOP
PU
BACK
S E T
SET
N E X T
Copyarea1
1 : Read VFD
2 : Write VFD
3 : Verifying
STOP
PU
BACK
S E T
SET
N E X T
A name (up to 9 letters) can be entered for the selected area.
Turn
to select "0 to 9", "A
to Z", ".", "_", "/" or "(space)".
5
Press
to move the
(→)
cursor. Press
after
(SET)
completing the input.
A confirmation screen appears
for overwriting the selected
area. Press
to execute
6
(SET)
the copy.
1 : Read VFD
Name:
ABCDEFGHI
▲
STOP
PU
BACK
S E T
SET
N E X T
1 : Read VFD
ABCDEFGHI
Overwrite Area 1
SET
: Exec
BACK : Cancel
STOP
PU
BACK
S E T
S E T
S E T
S E T
SET