Compressor Discharge Or Top 1/2 Temperature Sensor Error - Samsung AM080FXWANR Service Manual

System air conditioners outdoor unit
Hide thumbs Also See for AM080FXWANR:
Table of Contents

Advertisement

Troubleshooting
4-3 Appropriate Measures for Different Symptom (cont.)

4-3-20 Compressor Discharge or Top 1/2 Temperature sensor error

Outdoor unit
display
Duct, Cassette (1/2 Way),Console, Celing
Operation Defrost
Indoorunit
display
※ ● : ON ◑ : Flash ×: OFF
Judgment
∙ Detect according to temperature detected with the compressor discharge pipe temperature thermistor.
Method
Cause of
∙ Compressor Discharge or Top Temperature sensor defective. (Open/Short)
problem
1. Cause of problem
Compressor
discharge or Top temperature sensor
connector (CN43, CN45)
connected to PBA?
After separating the Compressor Discharge or
Top Temperature sensor connector from the
PBA, measure the resistance value between
the two terminals.
Is the resistor value matching with
"NOTE1" table?
Restart operation after replace the PBA
Samsung Electronics
(Compressor 1 Discharge)
(Compressor 1 Top)
Timer
Fan Filter/MPI Operation Defrost
×
×
×
Yes
Yes
(Compressor 2 Discharge)
(Compressor 2 Top)
Cassette (4/Mini4 Way)
Timer
×
No
Restart operation after connecting
the connector to PBA
Resistance value
Resistance value
measure part
measure part
TOP1
TOP2
TOP1 : CN43 (3, 4)
TOP2 : CN45 (5, 6)
DIS1 : CN43 (1, 2)
DIS2 : CN45 (3, 4)
No
Replace this part as it is the defective
of the Compressor Discharge or
Top Temperature sensor itself.
Wall-mounted (NeoForte)
Filter Operation
Timer
×
TOP1
TOP2
NOTE1
Temperature(°C)
Resistance(KΩ)
130
120
100
80
60
25
20
10
0
Turbo
×
8.9
11.2
18.5
32.0
59.0
200.0
242.0
362.0
553.0
104

Advertisement

Table of Contents
loading

Table of Contents