Power cord connections
WARNING
Risk of electric shock!
Frame grounded to neutral of appliance
through a link. Grounding through the neutral
conductor is prohibited for new branch-circuit
installations (1996 NEC); mobile homes; and
recreational vehicles, or in an area where local
codes prohibit grounding through the neutral
conductor. For installations where grounding
through the neutral conductor is prohibited:
a- Disconnect the link from the neutral;
b- Use grounding terminal or lead to ground
unit; and
c- Connect neutral terminal or lead to branch
circuit neutral in usual manner (when the
appliance is to be connected by means of a
cord kit, use 4-conductor cord or conduit for
this purpose) See fig.9.
•Do not use an extension cord.
IMPORTANT:
Do not loosen the factory installed nut connec-
tions which secure the range wiring to terminal
block. Electrical failure or loss of electrical
connection may occur if these 3 nuts are
loosened or removed.
Power cord
Train relief installation
A ground strap is installed on this range which
connects the center terminal of the neutral ter-
minal block to the range chassis. The ground
strap is connected to the range by the center,
lowest screw. See Figure 9. The ground strap
must not be removed unless National, State or
Local Codes do not permit use of a ground strap.
Note: If the ground strap is removed for any
reason, a separate ground wire must be con-
nected to the separate ground screw attached to
the range chassis and to an adequate ground
source.
3 & 4-wire permanent wire connections
3-wire permanent connection - follow steps in, 2
and 5 below. 4-wire permanent connection —
follow all steps below.
Before wiring the range, review the suggested
power source location drawings in Figure 2. If
connecting to a 4-wire electrical system
24/EN
1. Follow the manufacturer's Installation In-
structions supplied with the strain relief
clamp and install.
2. Strip insulation away from the ends of the
permanent wiring for line 1, line 2 and neu-
tral; also strip ground wire on 4-wire con-
nections. Tighten all 3 or 4-wi re leads to the
terminal block. Follow wire locations shown
in Figure 10.
IMPORTANT DO NOT LOOSEN the factory
installed at connections which secure the
range wiring to the terminal block. Electrical
failure or loss of electrical connection may
occur if these 3 nuts are loosened or re-
moved.
Note: For 3-wire permanent connection skip
steps 3 and 4 and continue with step 5.
3. Disconnect the ground strap. Remove the
factory installed ground screw and plate to
release the factory installed copper ground
strap from frame of the range. Cut and dis-
card the copper strap from the terminal block.
KEEP the ground screw, ground plate and go
to step 4.
4. Connect the green ground wire lead to the
frame of the range using the ground screw
and plate as shown in Figure . B e sure to in-
stall using the same hole in the frame where
the ground screw was originally installed.
5. Make sure all connections are tightened
securely and replace the rear access cover.
See Figure .
Note: Non-terminated field wire compression
connections must be set at approximately 90
in./lbs.