shielded copper or aluminum cable), or by means
of a power supply cord kit. Only a power supply
cord kit rated at 120/ 240 volts and 40 or 50
amperes terminating in tinned leads and marked
for use with ranges shall be used. If a 50 Amper
cord is used it must be marked for use with a 1 3/8
inches diameter opening.
Cord must have either 3 or 4 conductors to match
electric receptacle (Use copper or Aluminum
Conductors).
WARNING:
Risk of fire or electrical shock exists if an
incorrect size appliance cord kit is used or the
Installation manual or strain relief clamp are
disregarded.
WARNING:
Do not loosen the nuts which secure the facto-
ry-installed range wiring to the terminal block
while connecting range. Electrical failure or loss
of electrical connection may occur.
When installed where it is not permitted to ground
through the neutral, a 4-conductor cord must be
used or cable assembly. See manufacturer's in-
structions.
The main supply data must correspond to the data
specified on the rating plate of the appliance.
The rating plate is either seen when the door is
opened.
3 & 4 -wire electrical wall receptacle types
& recommended mounting orientation on
wall
Figure A illustrates 4-wire receptacle required for
new branch circuit installation (1996 NEC) mobile
homes, and recreational vehicles or where local
codes do not allow grounding thru the neutral.
Figure B illustrates 3-wire receptacle that is allowed
in areas that allow grounding through neutral.
A) 4-wire wall
receptacle
Access to terminal block
1
Terminal block
2
Cover
Loosen the screws on rear access cover and take
off the terminal block cover.
After completing connections put terminal block
cover to the original location and tighten the
screws.
B) 3-wire wall receptacle
(10-50R)
23/EN