Epson TM-U200 series Technical Manual page 146

Hide thumbs Also See for TM-U200 series:
Table of Contents

Advertisement

C o n fid e n tia l
2. Connect the lead wire assembly's connector to the near-end detector and attach it to the
near-end detector frame with the screw.
3. Decide whether you want to install the spacers.
The amount (A) of paper remaining (including the paper roll core) when the near-end
detector senses a paper near-end is changed by the spacers.
The amount (A) with the spacers: 3 to 4 mm (0.12 to 0.16")
The amount (A) with the spacers: 6 mm (0.24")
The value of (A) is obtained by calculation only. Therefore, it may not be appropriate for all
printers.
5-46 Disassembly, Assembly, and Adjustment
Lead wire assembly
Near-end detector
lever
CBB-tite (M2x8)
[0.1 to 0.2 N • m
(1 to 2 kgf • cm)]
Near-end detector
Near-end detector
frame
d
A
Rev. A