6.3. Installation as a fill level sensor

6.3. Installation as a fill level sensor
6.3. Installation as a fill level sensor
6.3. Installation as a fill level sensor
Install the sensor on the
same height or lower than
the bottom inlets of the
reservoir and connect one
of the bottom inlet to the
port "high" of the sensor.
For accurate sensor read-
ings, keep tubing length
to a minimum.
Additionally,
either
port "low" of the sensor
(types ∆40 / ∆100 /
∆500 / ∆1000 only) has
to be connected to a top
port of the reservoir or a
pressure
equalization
membrane has to be installed into a top port of the reservoir (valid for all sensor
types). If the port "low" is used, the hose connecting this port to the top of the
reservoir has to be filled with air. Otherwise, the sensor will produce erratic read-
ings and the actual fill level may differ significantly from sensor reading! Aqua
Computer therefore strongly recommends using a pressure equalization mem-
brane! Fittings and pressure equalization membrane are not included in delivery
and have to be bought separately!
For electrical connections and configuration of the sensor please refer to chapter
eight and following chapters.

6.4. Installation as a differential pressure sensor

6.4. Installation as a differential pressure sensor
6.4. Installation as a differential pressure sensor
6.4. Installation as a differential pressure sensor
Connect both sensor ports to the coolant lines directly prior and behind the com-
ponent you want to monitor (for example using suitable T connectors). Connect
the port "high" to the spot where you expect the higher relative pressure. You can
use the following table as reference:
Component
Component
Component
Component
Filter
Water block
Pump
For electrical connections and configuration of the sensor please refer to chapter
eight and following chapters.
- 8 -
the
connect „high" to
connect „high" to
connect „high" to
connect „high" to
Inlet port
Inlet port
Outlet port