Aqua Computer D5 NEXT User And Installation Manual

Aqua Computer D5 NEXT User And Installation Manual

Hide thumbs Also See for D5 NEXT:
Table of Contents

Advertisement

aqua
computer
User and installation manual
User and installation manual
User and installation manual
User and installation manual
All information contained in this manual is subject to change without prior notice.
© 2019-2020
D5 NEXT
aquasuite version X.17
Current as of April 2020
All rights reserved.
Aqua Computer GmbH & Co. KG
Gelliehäuser Str. 1, 37130 Gleichen
D5 NEXT
ENGLISH: PAGE 1
DEUTSCH: SEITE 31
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D5 NEXT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aqua Computer D5 NEXT

  • Page 1 DEUTSCH: SEITE 31 Current as of April 2020 All information contained in this manual is subject to change without prior notice. All rights reserved. © 2019-2020 Aqua Computer GmbH & Co. KG - 1 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 2 10.1. Pump mode power preset............14 10.2. Pump mode temperature set point..........15 10.3. Pump mode curve controller............15 10.4. Pump mode flow controller............15 10.5. General pump settings..............15 - 2 - Aqua Computer GmbH & Co. KG © 2019-2020 Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 3 15.3. Display pages................23 16. Profiles..................23 16.1. Manual profile selection............23 16.2. Automatic profile selection............23 16.3. Profile configuration..............23 17. System settings D5 NEXT............23 17.1. Device information..............23 17.2. Factory defaults................24 17.3. aquabus/RGBpx configuration...........24 17.4. Firmware update and language selection (aquasuite only).....24 18. Playground (aquasuite)..............24 18.1.
  • Page 4 Preface Preface The D5 NEXT pump is built for longevity and to match the highest quality stan- dards. It has been particularly designed for PC water cooling systems. The pump is based on the Laing/Lowara/Xylem D5vario pump and the stainless steel top with ceramic ball, the pump rotor and part of the electronics and housing are manu- factured by Laing/Lowara/Xylem.
  • Page 5 Aqua Computer GmbH & Co. KG customers using or selling this product for use in such application do so at their own risk and agree to fully indemnify Aqua Computer GmbH &...
  • Page 6 The corresponding connector on the motherboard is usually a 9 pin connector with two independent USB ports. Both rows of 4/5 pins can be used to connect an USB device. - 6 - Aqua Computer GmbH & Co. KG © 2019-2020 Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 7 Connector “Bus” for aquabus or RGBpx Depending on configuration, this connector can either be used for communication with other Aqua Computer devices or to connect RGBpx products (up to 90 ad- dressable LEDs). Simultaneous use of both functions is not possible!
  • Page 8 Configuration using USB connection Configuration using USB connection The D5 NEXT can be connected to a PC via USB interface and can then be config- ured using the aquasuite software. Comprehensive visualization and logging op- tions are also available in the aquasuite software. However, an USB connection is not required for operation.
  • Page 9 PC. These pages can be individually modified and new pages can be created. Within one overview page, data from all connected devices can be accessed. © 2019-2020 Aqua Computer GmbH & Co. KG - 9 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 10 If the currently selected overview page is unlocked for editing, right-click an ele- ment and select “Settings”. You may also double click the element. - 10 - Aqua Computer GmbH & Co. KG © 2019-2020 Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 11 More complex controls such as data bindings and animations are also available but will require some programming experience for configuration. © 2019-2020 Aqua Computer GmbH & Co. KG - 11 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 12 This includes data from connected USB devices as well as hardware data supplied by the Aqua Computer background service. Displayed data may be filtered using the text box next to the magnifier icon, a chart shows the develop- ment over a maximum of ten minutes.
  • Page 13 This function can be used to zoom in and out. Use the mouse wheel or select the area to be displayed. You can reset the zoom settings by dou- ble-clicking in the chart area. © 2019-2020 Aqua Computer GmbH & Co. KG - 13 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 14 Pump configuration Pump configuration aquasuite: Select “Pump” from the device list below the “D5 NEXT” entry. In the upper area, current pump data is displayed as plain text as well as in a diagram. Select the desired mode of operation below the diagram.
  • Page 15 The “Maximum rotation speed for bar graph and chart” setting applies only to dia- gram scaling within the aquasuite and has no effect on the pump function. © 2019-2020 Aqua Computer GmbH & Co. KG - 15 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 16 Pump behavior with aquabus connection to an aquaero Pump behavior with aquabus connection to an aquaero As soon as an aquabus connection between the D5 NEXT and an aquaero 5/6 is established, the pump function is solely controlled by the aquaero. All settings in the D5 NEXT regarding pump function will be ignored.
  • Page 17 Fan behavior with aquabus connection to an aquaero Fan behavior with aquabus connection to an aquaero As soon as an aquabus connection between the D5 NEXT and an aquaero 5/6 is established, the fan output is solely controlled by the aquaero. All settings in the D5 NEXT regarding fan function will be ignored.
  • Page 18 The six RGBpx LEDs integrated into the Controller unit are assigned to a dedicated LED controller. For RGBpx components connected to the D5 NEXT, a total of four independent LED controllers can be configured to control sections of the connect- ed LEDs.
  • Page 19 Options for flow rate measurement Options for flow rate measurement The D5 NEXT is able to continuously calculate the current flow rate from a variety of pump parameters after an initial calibration process. Aqua Computer refers to this method as “virtual flow sensor”.
  • Page 20 Mechanical flow sensor Mechanical flow sensor Calibration values for sensors sold by Aqua Computer can conveniently be select- ed from a drop-down list. Select the appropriate entry in the “sensor type” selector for the flow sensor connected to the D5 NEXT.
  • Page 21 14. Alarm configuration Alarm configuration Alarm configuration Alarm configuration aquasuite: Select “Alarms” from the device list below the “D5 NEXT” en- try. Device menu: Select “Alarms” from the menu list and confirm by pressing the middle key. 14.1.
  • Page 22 Display configuration and information pages Display configuration and information pages Display configuration and information pages aquasuite: Select “Display” from the device list below the “D5 NEXT” en- try. Device menu: Select “Display” from the menu list and confirm by pressing the middle key.
  • Page 23 The profile management can be used to to save four configurations as profiles and activate them manually or automatically. Profile management is a software feature of the aquasuite and requires a USB connection to the D5 NEXT. 16.1. 16.1.
  • Page 24 Address 30 and 31 are available. Please note that aquastream ULTIMATE and aquastream XT as well as D5 NEXT share resource assignments in the aquabus device handling of the aquaero. A combined maximum of two pumps of these types can be managed by the aquaero.
  • Page 25 Hotkeys are key combinations that will be processed system-wide and can activate global profiles or desktop pages. The configured key combinations will be regis- © 2019-2020 Aqua Computer GmbH & Co. KG - 25 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 26 Click the entry “aquasuite web” to publish data on the internet or import data from the internet. The server for this service is operated by Aqua Computer and provid- ed for use with the aquasuite, without warranty for error free operation or perma- nent availability.
  • Page 27 Data import Data import To import a data set from the Aqua Computer server, the “access key” of the data set is required. The access key can be found in the aquasuite on the computer providing the data in the “Data access” section.
  • Page 28 Service administration Service administration The background service configures special USB settings for all connected Aqua Computer devices, provides hardware data, software sensors, pro- file management and aquasuite web and should therefore always be ac- tive. The hardware monitoring features of the background service can be disabled for specific categories if errors occur.
  • Page 29 Care instructions Use a dry and soft cloth for cleaning. All electronic components and headers must not get in contact with coolant or water! © 2019-2020 Aqua Computer GmbH & Co. KG - 29 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 30 24/7. To get in direct contact with our customer support team, we offer several options: Email: support@aqua-computer.de Postal address: Aqua Computer GmbH & Co. KG Gelliehäuser Str. 1 37130 Gleichen Germany Tel: +49 (0) 5508 9749290 (9-16 h CET, German and English language) - 30 - Aqua Computer GmbH &...

Table of Contents

Save PDF