Fig. 401; Fig. 402 Technical Data For Circulating Pump - Webasto Thermo Top V Workshop Manual

Table of Contents

Advertisement

Thermo Top V
4
Technical data
Except where limit values are specified, the technical data listed in the tables refer to the usual heater tolerances of ± 10%
at an ambient temperature of + 20 °C and at the rated voltage and in rated conditions. All electrical components are
designed for a nominal voltage of 12 volts.
Heater
Type test permit
Model
Heat output
Fuel
Fuel consumption
Rated voltage
Operating voltage range
Nominal power consumption without
circulating pump (without vehicle fan)
Max. ambient temperature:
Heater:
- Operation
- Storage
Perm. operating pressure (heat carrier)
Capacity of the heat exchanger
Minimum capacity of the circuit
Minimum flow rate for the heater
CO
in exhaust gas
2
(permitted function range)
Heater dimensions
Weight
Circulating pump
Volume flow against 0.14 bar
Rated voltage
Operating voltage range
Rated power consumption
Dimensions, circulating pump
Weight
Visit www.butlertechnik.com for more technical information and downloads.
Operation
EMC
heater
Full load
Partial load
Full load
Partial load
Full load
Partial load
Fig. 401 Technical data for Thermo Top V

Fig. 402 Technical data for circulating pump

www.butlertechnik.com
Thermo Top V Petrol
e1*72/245*2006/96*1232*__
e1*2001/56*2006/119*0018*__
Water heater with atomization burner
5.0 kW
3 kW
Petrol
EN 228
DIN 51625
0.67 l/h
0.39 l/h
12 V
10.5 to 16 V
34 W
24 W
-40 to + 50 °C
-40 to + 120 °C
0.4 to 2.5 bar
0.075 l
4.00 l
150 l/h
8 to 13.0 % by vol.
Length 222 mm
Width 91 mm
Height 144/180 mm
2.1 kg
4849
500 l/h
12 V
9 to 16 V
12 W
Length 107 mm
Diameter 48.5 mm
0.35 kg
Technical data
Thermo Top V Diesel
Diesel
EN 590
0.60 l/h
0.35 l/h
-40 to + 80 °C
-40 to + 120 °C
4847 Econ
450 l/h
13.9 W
Length 112 mm
Diameter 48.5 mm
0.285 kg