Fig. 203 Standard Connector Plate With Amp Connector Basket; Fig. 204 Connector Plate With Fep Connector Basket; Fig. 205 Connector Plate For Vw Single Board With Fep Connector Basket; Diesel/Petrol Burner - Webasto Thermo Top V Workshop Manual

Table of Contents

Advertisement

General description
Connector plate variants
Fig. 203
Standard connector plate with AMP connector
basket
Fig. 204
Connector plate with FEP connector basket
Fig. 205
Connector plate for VW single board with FEP
connector basket
For connector assignment on control unit, see section 7.1.
202
Visit www.butlertechnik.com for more technical information and downloads.
AMP connec-
tor basket
FEP connector
basket
www.butlertechnik.com
2.2

Diesel/petrol burner

The processing of the fuel-air mixture and the actual com-
bustion take place in the burner. The fuel flows into the pre-
heating chamber with the shut-off valve opened, where it is
at first heated up. After exiting from the fuel needle, it is
atomised in a venturi nozzle through which primary air
flows. Additionally directed secondary air is routed into the
combustion chamber via the heat shield. The pilot flame is
ignited on the hot spot of the glow plug and then, after
slowly running up, leads to the ignition of the flame in the
full load operating mode. In the process, the heater is
dependent on the most bubble-free fuel delivery possible.
The start process differs in different ambient temperatures
ensuring that the heater starts with the minimum of smoke
emission.
Fig. 206
Diesel burner with solenoid valve (SV)
Fig. 207
Diesel burner with fuel preheating (FPH)