3
BOARD CONFIGURATION
Most station configuration parameters are altered through the Radio Service Software (RSS) with the exception of
some parameters for the following boards, which are configured through jumpers:
•
4-Wire Wireline Interface Board (CLN1203),
•
4-Wire Euro Wireline Interface Board (CLN1204),
•
Auxiliary I/O Board(CLN1206).
4-Wire Wireline Interface Board
.
Tone Remote Control
2-wire/4-wire configurations
Figure 6.
4-Wire Euro Wireline Interface Board
68P81096E37-N
06/28/05
Model CLN1203 WIB supports tone control of the station. CLN1203 pro-
vides a fixed impedance of 600Ω to the wireline. Figure 6 shows the jump-
er locations for tone control.
P10,
P12,
P14,
P16,
P11
P13
P15
P17
out
CLN1203 Wireline Interface Board Jumper Settings
Figure 7 shows the correct settings of impedance matching jumpers for the
model CLN1204 WIB, as determined by the country in which the station is
being operated. Incorrect jumper settings may violate local telecommuni-
cations authority regulations and place the equipment in an unapproved
status. Some countries also specify a maximum allowed line input level.
Refer to the RSS Online Help, under Line Level.
P2
T1
P11
P10
C74
P15
P14
C84
P13
P12
P17
P16
T2
P6
Installation
C15
21