Dimension A (2.4.1.3.)
The height of the vessel bottom in Level Units when the bottom is conical, pyramidal, parabolic,
spherical, or flat -sloped. If the vessel is horizontal
with parabolic ends, the depth of the end. See Vessel Shape (2.4.1.1.) for an illustration.
Values
Related Parameters
Dimension L (2.4.1.4.)
Length of the cylindrical section of a horizontal parabolic end vessel, in Level Units. See Vessel
Shape (2.4.1.1.) for an illustration.
Values
Related Parameters
XY index (2.4.1.5.)
Level/Volume breakpoints allow you to define a complex vessel shape as a series of segments.
A value is assigned to each level breakpoint and a corresponding value is assigned to each
volume breakpoint.
Volume values are defined in volume units and can be percent or volumetric; level values are
defined in level units, and can be percent or linear. See Level Unit (2.3.2.) and PV Units
(volume/level) (2.3.3.).
Level values
Volume values
Enter up to 32 level breakpoints, where the corresponding volume is known. The values
corresponding to 100% and 0% levels must be entered. The breakpoints can be ordered from
top to bottom, or the reverse.
SITRANS LR250 (PROFIBUS PA)
Operating Instructions, 08/2014, A5E32221386-AC
Range: 0.0000 to 999999 in Level Units
Default: 0.0
Vessel Shape (2.4.1.1.)
Range: 0.0000 to 999999 in Level Units
Default: 0.0
Vessel Shape (2.4.1.1.)
Range: -999999.00 to 999999.00 (m, cm, mm, ft, in, %)
Default: 0.0
Range: -999999.00 to 999999.00 (% or volumetric units)
Default: 0.0