Installing/mounting

4.4 Installation instructions

4.4
Installation instructions
Pressure applications
Danger to personnel, system and environment can result from improper installation.
• Improper installation may result in loss of process pressure.
Improper installation
Danger to personnel, system and environment can result from improper installation.
• Installation shall only be performed by qualified personnel and in accordance with local
NOTICE
Device handling
Damage to device may result from improper handling.
• Handle the device using the enclosure, not the process connection or tag, to avoid
• Take special care when handling the threaded PVDF and Hygienic or Flanged
Note
• For European Union and member countries, installation must be according to
ETSI EN 302372.
• Refer to the device nameplate for approval information.
Note
The outer part of the lens on the flanged encapsulated antenna version may not appear to lie
flush before installation and this is normal. This will flatten after installation and will not impact
the performance of the device.
34
WARNING
WARNING
governing regulations.
damage.
encapsulated antennas. Any damage to the antenna surface, particularly to the tip/lens,
could affect performance. (For example, do not sit device on its lens antenna.)