Re-Install The Front Fan Trays; Lower Front Fan Tray; Upper Front Fan Tray; Re-Install The Rear Fan Trays - Cisco ASR 5500 Installation Manual

Hide thumbs Also See for ASR 5500:
Table of Contents

Advertisement

Re-install the Front Fan Trays

Re-install the Front Fan Trays

Lower Front Fan Tray

Step 1
At the front of the chassis, align the fan tray within the lower chassis opening. With the unit resting on the bottom rail
of the opening, push inward until it is seated in the midplane.
Step 2
Use a #1 Phillips screwdriver to tighten the two captive screws that secure the fan tray to the chassis.
Step 3
Reinstall the lower access cover.

Upper Front Fan Tray

Step 1
Align the fan tray within the upper chassis opening. With the unit resting on the bottom rail of the opening, push inward
until it is seated in the midplane.
Step 2
Use a #1 Phillips screwdriver to tighten the two captive screws that secure the fan tray to the chassis.
Step 3
Reinstall the upper access cover.

Re-install the Rear Fan Trays

Lower Rear Fan Tray

Step 1
At the rear of the chassis, align the fan tray within the opening at the bottom rear of the chassis.
Step 2
With the unit resting on the bottom rail of the opening, slowly slide the fan tray into the chassis along the guides until it
is seated firmly in the midplane connectors.
Step 3
Reinstall the lower access cover.
ASR 5500 Installation Guide
46
Chassis Installation

Advertisement

Table of Contents
loading

Table of Contents