Technical Specifications
Table 4: Environmental Parameters
Parameter
Temperature
Humidity
Altitude
Acoustic Noise
Notes:
1 Short-term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days
in 1 year. (This refers to a total of 360 hours in any given year, but no more than 15 occurrences during
that 1-year period.)
2 Within GR-63 limits for unattended operation.
3 Measured during GR-63 R4-97 testing.
4 Measured with DPC2 installed.

Environmental Standards

The ASR 5500 has been successfully tested for compliance with the environmental standards listed in table
below.
Subparameter
Range
Operating
0 degrees C to +40 degrees C (32 degrees F to 104 degrees F)
1
Short Term
-5 degrees C to +50 degrees C (23 degrees F to 122 degrees F)
Storage
-40 degrees C to +70 degrees C (-40 degrees F to 158 degrees
F)
Operating
20 to 80 percent non-condensing
Storage
10 to 95 percent non-condensing
Operating
197 ft. (60m) below to 5,905 ft. (1,800m) above sea level,
maximum 40 degrees C (104 degrees F)
5,905 ft. (1,800m) to 13,123 ft. (4000m) above sea level,
maximum 30 degrees C (86 degrees F)
Non-operating
197 ft. (60m) below to 49,212 ft. (15,000m) above sea level
23 degrees C (73.4
81 dB [L
degrees F)
26 degrees C (78.8
83 dB[L
degrees F)
27 degrees C (80.6
81 dB [L
degrees F)
Max. Fan Speed
96.5 dB [L
26 degrees C (78.8
degrees F)
Environmental Standards
2
]