Rs-232 Settings - Eiki EIP-UJT100 Service Manual

Dlp digital projector
Hide thumbs Also See for EIP-UJT100:
Table of Contents

Advertisement

3-2. RS-232 Settings

Interface and Requirements
The RS-232 Commands use only ASCII characters which can be entered
using a typical terminal emulator like Windows HyperTerminal with
the following setting:
Note that each input character will be echoed on the terminal by MCU and
there is no need to set the local echo "ON" with the terminal setting.
 When using
baud rate
 When using
use baud rate
Bits per second:
Data bits:
8
Parity:
None
Stop bits:
1
Flow control:
"Delta Mode"
"115200"
to set and communicate.
"Normal Mode"
"19200"
to set and communicate.
19200 (Delta Mode: 115200)
None
to operate projector, please use