Specifications - Firepower FP 125 Operating Manual & Installation Manual

Portable mig/flux cored welder
Hide thumbs Also See for FP 125:
Table of Contents

Advertisement

FIREPOWER FP 125,135,165

2.05 Specifications

Description
Package System Part Number
Power Source Weight
Power Source Dimensions HxWxD
Number of Phases
Frequency
Flexible Supply Cable Size
Supply Lead Plug Type
Nominal Input Voltage
Rated kVA @ 100% Duty Cycle
Rated Input Current
Maximum Input Current
Generator Requirements
Supply VA @ max. output
Open Circuit Voltage Range
Output Current Range
Duty Cycle Period
Number of Output Voltage Values
Minimum Mains Circuit to suit factory fitted Plug &
Lead (Weld Current @ Duty Cycle)
Maximum Mains Circuit to suit factory fitted Plug &
Lead (Weld Current @ Duty Cycle)
The recommended time delay fuse or circuit breaker size is 20 amp. An individual branch circuit capable of carrying 30 am-
peres and protected by fuses or circuit breaker is recommended for this application. Fuse size is based on not more than 200 percent
of the rated input amperage of the welding power source (Based on Article 630, National Electrical Code)
Firepower continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the
specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment
previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items.
The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above spec-
ifications due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured components,
installation location and conditions and local power grid supply conditions.
INTRODUCTION
FP 125
1444-0324
47.4 lb (21.5 kg)
7 ft (2.2 m) 14AWG
5-15P
120V AC
5kVA
15A (60A@40%)
38A (110A@10%)
# 5kVA
# 4.6kVA
16 – 30V
40 – 125A
15A (60A@40%)
38A (110A@10%)
Wire Size Range
Steel
Stainless Steel
.030" - .035"
Flux Core
(0.8 - 0.9mm)
Table 2-1: System Specifications
2-2
FP 135
1444-0326
52.9 lb (24.0kg)
12 x 9.75 x 17.5" ( 304.8 x 247.7 x 444.5mm)
1 Ø
60Hz
7 ft (2.2 m) 14AWG
5-15P
120V AC
6kVA
15A (60A@60%)
50A (120A@13%)
# 6kVA
# 5kVA
16 – 32V
39 – 135A
10 Minutes
4
15A (60A@60%)
50A (120A@13%)
.023" - .030" - .035"
(0.6 - 0.8 - 0.9mm)
.023" - .030" - .035"
(0.6 - 0.8 - 0.9mm)
.030" - .035"
(0.8 - 0.9mm)
FP 165
1444-0328
58.1 lb (26.4 kg)
7.5 ft (2.5 m) 14AWG
6-50P
230V AC
7kVA
22.5A (120A@25%)
35A (155A@15%)
# 7kVA
# 6.8kVA
15 – 30V
36 – 165A
22.5A (120A@25%)
35A (155A@15%)
.023" - .030" - .035"
(0.6 - 0.8 - 0.9mm)
.030" - .035"
(0.8 - 0.9mm)
Manual 0-5123

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp 135Fp 165Fp 95 fc

Table of Contents