Option
Description
LIMIT NUMBER
Allows the user to apply a date
OF RECORDS IN
range limit to the Transmit All
TRANSMIT ALL
function in the i-STAT 1
analyzer.
UPLOAD
Options are Off, or every 1 to
SCHEDULE
65535 hours. If enabled, the
analyzer's behavior if the
schedule is not met can be
specified. Behavior Options are
Warn User (start-up warning
message) or Lockout (testing
disabled until upload occurs).
Preference Window for Operator and Patient ID Options
Option
Description
OPERATOR ID
Minimum and maximum
allowed operator ID length
(scanned or manually entered).
REPEAT ID ENTRY Operator must enter ID twice.
Analyzer prompts operator to
start again if IDs do not match.
INCLUDE ID ON
Enables/Disables printing of
PRINTOUT
operator IDs on printouts from
the Martel printer.
BARCODE
The type of barcodes used for
OPTIONS
Operator ID. See table below.
MANUAL ENTRY
Options are None, ISBN
CHECK DIGIT
Modulus 11 Check, and IBM
Modulus 10 Check.
INVALID
Behavior of analyzer when
OPERATOR
Operator ID not in stored list or
certification date expired
Options are: Not enabled
(continue without warning),
Warn User (prompt to
continue), and Lockout (block
testing until a valid Operator ID
is scanned/entered).
PATIENT ID
Minimum and maximum
allowed patient ID length
(scanned or manually entered).
REPEAT ID ENTRY Operator must enter patient ID
twice. Analyzer prompts
operator to start again if IDs do
not match.
CDS-24
Default
Not enabled
Off (no warning
or lockout.)
Default
Min = 0,
Max = 15
Enabled: repeat
required
Enabled
All barcode
types
None
Continue without
warning
Min = 0,
Max = 15
Enabled
Central Data Station
Comments
Prevents operators from sending older
patient records that may have already been
deleted from the Central Data Station.
If no upload schedule is specified and the
Memory Full warning is ignored and
Auto-transmit disabled, data will
eventually be overwritten. However, if an
analyzer has not been used and the upload
interval is exceeded, this analyzer will be
inoperable if the lockout option is used.
Comments
If operator IDs are a fixed length, both
settings should equal the ID length.
This option can be set for manual and/or
scanned ID Entry.
Disabling printing of operator IDs can
prevent uncertified operators from
learning the IDs of certified operators.
Check digit algorithms are given in HL7
Specification, Section 2.9.5.3.
Do not enable if the Use Operator List
option is disabled.
Separate Actions can be chosen for
Certification Expired or Operator Not On
List.
If operator IDs are a fixed length, both
settings should equal the ID length.
This option can be set for manual and/or
scanned ID entry.