installation
|
10

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related ires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this ireplace and vent system be installed only in accordance with these instructions.
Clearance:
A: Mantel Height (min.)
B: Sidewall (on one side)
C: Ceiling
(room and/or alcove)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
G: From Floor
Note:
D
A
G
F
Alcove
Regency Horizon ® HZ40E-10 Gas Fireplace
10 |
Dimension
17" (330mm)
Top of Fireplace Opening
8" (203mm)
Side of Fireplace Opening
22" (559mm)
Top of Fireplace Opening
13" (330mm)
22" Above Fireplace Opening
84" (2134mm)
Sidewall to Sidewall (Minimum)
36" (914mm)
Front to Back Wall (Maximum)
27" (686mm)
0"
F
B
E
Installed Close
to Floor
E
Measured From:
Top of Fireplace Opening
No hearth required
The top, back and sides of the ireplace are deined by
standofs. The metal ends of the standof may NOT be
recessed into combustible construction.
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this ireplace and vent
system be installed only in accordance with these instructions.
Flue Clearances to Combustibles
Horizontal - Top
Horiztonal - Side
Horiztonal - Bottom
Vertical
Passing through wall/
floor/ceiling - when
irestop is used.
The HeatWave Duct Kit and the Heat
Release Kit have diferent clearance
and framing requirements, check
the HeatWave and Heat Release
Heat Release Kit
manual for details.
Installed close
to ceiling.
Caution Requirements
WARNING
Fire hazard is an extreme risk
3"
2"
2"
2"
1-1/2"