Regency Horizon HZ54 Owners & Installation Manual

Regency gas fireplaces owners and installation manual
Hide thumbs Also See for Horizon HZ54:
Table of Contents

Advertisement

Quick Links

Regency Horizon
www.regency-fi re.com
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-751a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
HZ54
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you
supplier, call the fi re department.
Owners &
Installation Manual
MODELS: HZ54-NG Natural Gas
HZ54-LP Propane
cannot reach your gas
10/31/08

Advertisement

Table of Contents
loading

Summary of Contents for Regency Horizon HZ54

  • Page 1 Regency Horizon Gas Fireplace www.regency-fi re.com WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Manufactured Mobile Home Requirements

    To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The HZ54 has been ® designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
  • Page 3: Table Of Contents

    Gas Pipe Pressure Testing ...29 S.I.T. Valve Description ...29 Aeration Adjustment ...30 Wiring Diagram ...30 Optional Wall Thermostat ...31 Optional Remote Control ...31 HZ54 Regency Horizon Gas Fireplace TABLE OF CONTENTS Optional Wall Switch ...31 GT Remote Features ...32 GT Remote Wiring Diagram ...32 Optional Stainless Steel Panel Installation ...33...
  • Page 4: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. HZ54 Regency Horizon Gas Fireplace...
  • Page 5: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. HZ54 Regency Horizon Gas Fireplace...
  • Page 6: Dimensions

    DIMENSIONS UNIT DIMENSIONS FACEPLATE & DOOR FRAME OVERLAY DIMENSIONS HZ54 Regency Horizon Gas Fireplace...
  • Page 7: Installation

    ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. HZ54 Regency Horizon Gas Fireplace YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
  • Page 8: Installation Checklist

    Have an authorized inspector, dealer, or installer review your plans before installation. Note: For vent terminations refer to "Exterior Vent Termination Locations" section. HZ54 Regency Horizon Gas Fireplace...
  • Page 9: Clearances

    E: Alcove Width 83" (2108mm) F: Alcove Depth 36" (914mm) NON-COMBUSTIBLE REQUIREMENTS HZ54 Regency Horizon Gas Fireplace CLEARANCES if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fi replace and vent system be installed only in accordance with these instructions.
  • Page 10: Mantel Clearances

    Combustible mantel leg clearances as per diagram: MANTEL CLEARANCES 13" (330mm) 3 ½" (89mm) 1" (25mm) 30” Top of Fireplace 28-1/8” Opening To Unit Base Legs MANTEL LEG CLEARANCES Drywall Metal Stud (On Edge) Non-combustible Facing 21” Standoff 20” HZ54 Regency Horizon Gas Fireplace...
  • Page 11: Framing & Finishing

    (top and bottom) ensuring that the maximum thickness does not go beyond the 1-1/2" as shown in the diagram below. The faceplate will not be able to be mounted if material is beyond 1-1/2". HZ54 Regency Horizon Gas Fireplace FRAMING & FINISHING 5) If material such as brick, stone, etc extends past the faceplate depth, when fi...
  • Page 12 Gas Connection Height Gas Connection Inset Gas Connection Opening Width HZ54 46-5/8” (1184mm) 60” (1524mm) 22” (559mm) 51” (1295mm) 72" (1829mm) 101-7/8 (2586mm) 44” (1118mm) 20” (508mm) 1-1/2” (38mm) 4” (102mm) 7-1/4” (184mm) 3-1/4” (83mm) HZ54 Regency Horizon Gas Fireplace...
  • Page 13: Unit Assembly Prior To Installation

    fi replace top line up. 3) Attach the standoff securely to the top with 2 screws per standoff (on opposite corners). HZ54 Regency Horizon Gas Fireplace INSTALLATION SIDE NAILING STRIPS The side and top nailing strips come attached to the unit.
  • Page 14: Vent Restrictor Position

    2” Vent Restrictor Set 3 VENT RESTRICTOR POSITION ent Restrictor Settings for HZ54-LP 4.25” Vent Restrictor Set 1 Factory Set Vent Restrictor (No adjustment required) 2” Vent Restrictor Set 3 1” Vent Restrictor Set 4 HZ54 Regency Horizon Gas Fireplace...
  • Page 15: Exterior Vent Termination Requirements

    INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS HZ54 Regency Horizon Gas Fireplace...
  • Page 16: Venting Arrangements

    2) Only Flex pipe purchased from FPI may be used for Flex installations. 3) Horizontal vent must be supported every 3 feet. 4) A wall thimble is mandatory for all horizontal terminations due to high temperatures. HZ54 Regency Horizon Gas Fireplace...
  • Page 17: Rigid Pipe Venting Systems

    FPI venting systems as well as Simpson Dura-Vent AstroCap XL is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trade- marks of Simpson Dura-Vent Co. Inc. HZ54 Regency Horizon Gas Fireplace Alternate Horizontal Termination...
  • Page 18: 5" X 8" Rigid Pipe Cross Reference Chart

    INSTALLATION 5” X 8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. HZ54 Regency Horizon Gas Fireplace...
  • Page 19 INSTALLATION HZ54 Regency Horizon Gas Fireplace...
  • Page 20: Allowable Horizontal Terminations For Hz54-Ng

    Firestops are required at each fl oor level and whenever passing through a wall. • A wall thimble is mandatory for all horizontal terminations due to high temperatures. VENTING ARRANGEMENTS (two 45 elbows equal one 90 elbow). HZ54 Regency Horizon Gas Fireplace...
  • Page 21: Allowable Horizontal Terminations For Hz54-Lp

    • Firestops are required at each fl oor level and whenever passing through a wall. • A wall thimble is mandatory for all horizontal terminations due to high temperatures. HZ54 Regency Horizon Gas Fireplace VENTING ARRANGEMENTS Horizontal (Feet) Vent Restrictor...
  • Page 22 With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 9 feet total horizontal. Please note min. 1 foot between 90 elbows is required. Elbows Elbows HZ54 Regency Horizon Gas Fireplace...
  • Page 23 8' Min. 6' Min. 8' Max. 9' Min. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 1, no adjustment required. HZ54 Regency Horizon Gas Fireplace Elbows NG and LP elbows. With these options, max. total pipe length is 30 feet with min.
  • Page 24: Allowable Vertical Terminations For Hz54-Ng

    Rigid Pipe (Part # 770-994). VENTING ARRANGEMENTS Minimum length of pipe between elbows 12” (305mm) Horizontal (Feet) 12 12 Vent Restrictor on Set 3 Vent Restrictor on Set 2 Vent Restrictor on Set 1 Max. 10’ (3m)(centerline to centerline) HZ54 Regency Horizon Gas Fireplace...
  • Page 25: Allowable Vertical Terminations For Hz54-Lp

    Set 1 to Set 3 or Set 4 if required. Note: Must use optional fl ue adaptor when using Rigid Pipe (Part # 770-994). HZ54 Regency Horizon Gas Fireplace VENTING ARRANGEMENTS Minimum length of pipe between elbows 12”...
  • Page 26: Unit Installation With Horizontal Termination

    1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap. 10) Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7). Diagram 7 HZ54 Regency Horizon Gas Fireplace...
  • Page 27: Unit Installation With Vertical Termination

    3) A Firestop spacer must be installed in the fl oor or ceiling of every level. Diagram 3 HZ54 Regency Horizon Gas Fireplace 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed.
  • Page 28: Unit Installation

    Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area. ASTROCAP XL DIMENSIONS (946-623/P) HZ54 Regency Horizon Gas Fireplace...
  • Page 29: High Elevation

    IMPORTANT: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open fl ame for leak testing. HZ54 Regency Horizon Gas Fireplace PILOT ADJUSTMENT Periodically check the pilot fl ames. Correct fl ame pattern has three strong blue fl ames: 1 fl...
  • Page 30: Aeration Adjustment

    Wiring errors can cause improper and dangerous operation. CAUTION: Carbon will be produced if air shutter is tightly closed. Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. HZ54 Regency Horizon Gas Fireplace...
  • Page 31: Optional Wall Thermostat

    16 GA. 32 Ft. 18 GA. 20 Ft. 20 GA. 12 Ft. 22 GA. 9 Ft. HZ54 Regency Horizon Gas Fireplace Optional REMOTE CONTROL Use the Regency Remote Control Kit approved ® for this unit. Use of other systems may void your warranty.
  • Page 32: Gt Remote Wiring Diagram

    FPI Wall Switch & Cover Plate are white, not black as shown. REFER TO CODING INSTRUCTIONS IN THIS MANUAL spade connectors Green wire White wire Low Voltage Junction Box J-Box Slider Switch Receiver Wall Plate Red wire Black wire HZ54 Regency Horizon Gas Fireplace...
  • Page 33: Optional Stainless Steel Panel Installation

    Left Side Panel Fit side panel tab into slot Left side panel in position HZ54 Regency Horizon Gas Fireplace Before you start: Right side panel in position 2) Fit the back panel into position by clearing the pilot shield and fi t the tabs on the bottom left and right side of the back panel into the slots at the base of the fi...
  • Page 34: Glass Crystals Or Optional Ceramic Stones

    Use of any other type of pebbles or material can create a danger and will void warranty. White River Pebbles shown surrounding the Burner Natural River Pebbles shown surrounding the Burner INSTALLATION ON BURNER Glass Crystals shown on Burner Optional Ceramic Stones + Glass Crystals shown on burner. FOR FIREBOX BASE HZ54 Regency Horizon Gas Fireplace...
  • Page 35: Faceplate & Door Frame Overlay Installation

    2) Place 2 of the supplied magnets on the lower corners of the Door Frame Overlay, this will keep the Faceplate in postion after it has been installed. HZ54 Regency Horizon Gas Fireplace FACEPLATE & 3) Secure the left side mounting bracket to the backside of the faceplate as shown below.
  • Page 36 Also if necessary, the faceplate may be adjusted up and down by loosening the top screw as shown in the diagram below and sliding the plate up or down as required. First Mounting Slot (recommended) IMPORTANT NOTE Faceplate Mounting Slots HZ54 Regency Horizon Gas Fireplace...
  • Page 37: Operating Instructions

    fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. HZ54 Regency Horizon Gas Fireplace OPERATING INSTRUCTIONS LIGHTING PROCEDURE...
  • Page 38: Copy Of Lighting Plate Instructions

    DO NOT REMOVE THIS INSTRUCTION PLATE CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261) LIGHTING INSTRUCTIONS to “OFF”. Knob cannot be turned from to“PILOT”. TO TURN OFF GAS APPLIANCE to “OFF”. Do not force. 918-583 HZ54 Regency Horizon Gas Fireplace...
  • Page 39: Maintenance

    The glass should be cleaned when it starts looking cloudy. 3) The faceplate is fi nished in a heat resistant paint and should only be refi nished with heat resistant paint. Regency uses StoveBright ® Paint - Metallic Black #6309.
  • Page 40: Glass Door Removal

    5) Remove the glass door. a) Remove the 3 screws shown below at the bottom of the glass door b) Swing the door out 45 from the bottom from the bottom and lift up and out. HZ54 Regency Horizon Gas Fireplace...
  • Page 41: Dc Spark Box Battery Replacement

    Box. 5) Remove the AA battery and replace with a new one. 6) Reverse steps 4 to 1. HZ54 Regency Horizon Gas Fireplace DC SPARK BOX REPLACEMENT 1) Remove the faceplate by lifting it up off the hinges on the sides of the fi rebox.
  • Page 42: Valve Tray Replacement

    5) Remove the glass door. a) Remove the 3 screws shown below at the bottom of the glass door b) Swing the door out 45 from the bottom from the bottom and lift up and out. HZ54 Regency Horizon Gas Fireplace...
  • Page 43: Instructions For Hz54-Ng Unit Only

    8) Disconnect the ON/OFF connector wires from the valve. ON/OFF Connector Wires 9) Disconnect the DC Sparker leads at the valve. DC Sparker Lead HZ54 Regency Horizon Gas Fireplace MAINTENANCE 10) Unplug the Ignitor wire from the DC Sparker. Ignitor Wire 11) Remove the valve tray by undoing 12 screws.
  • Page 44: Instructions For Hz54-Lp Unit Only

    13) Remove the valve tray by undoing 12 screws. 14) Slighty lift out valve tray. 15) Disconnect the inlet gas line. 16) Replace valve and reverse steps. ON/OFF Connector Wires DC Sparker Lead Gas Inlet Line HZ54 Regency Horizon Gas Fireplace...
  • Page 45: Parts List

    Plate Relief Gasket 476-055 Valve Tray Gasket 521-035 Inner Flue Collar Gasket 940-359/P Flush Glass 476-011 Flush Glass 910-882 Wire (Valve to Burner ON/OFF) 948-409 Flue Collar 948-415 Lifting Handle 918-751 Manual HZ54 Regency Horizon Gas Fireplace MAIN ASSEMBLY PARTS LIST...
  • Page 46: Accessories

    Faceplate & Door Frame Overlay - Bright Stainless Steel 946-671 Cobalt Blue Glass Crystals 946-672 Natural River Pebbles 946-673 White River Pebbles 946-680 GT Profl ame Remote Control 910-576 Cover Wall Mount 910-572 Receiver GTM SIT w/Batt & Cover ACCESSORIES HZ54 Regency Horizon Gas Fireplace...
  • Page 47: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency unauthorized service persons or dealers.
  • Page 48 ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Horizon is a trademark of FPI Fireplace Products International Ltd. © Copyright 2008, FPI Fireplace Products International Ltd. All rights reserved. online at ® Printed in Canada...

This manual is also suitable for:

Horizon hz54-ngHorizon hz54-lp

Table of Contents