For example:
Figure 1: If the target path is to the right of the
receiver, and running parallel to the operator, the
right arrow will display.
Figure 2: If the target path is to the left and in front
of the operator (not running parallel to the receiver)
the arrow will point toward the top left side of
the display.
Figure 3: When the receiver crosses the target path,
a solid line will appear, instead of arrows, indicating
the target path and its orientation to the receiver
handle.
Before marking target path, always use Directional Peak (Dir Pk) or Special Peak (Spl
Pk) mode to verify location.
C. Special Peak (Spl Pk)
Locate/OK [5] + Cable/Pipe [SK] + Mode [SK] + Spl Pk [SK Toggle]
Special Peak Mode turns on only the peak antenna closest to the ground. Special Peak
Mode is used in applications such as very deep cables or pipes, or when the signal is too
weak for directional peak tracing.
Left or Right of Target Path
Directly Over Target Path
78-8130-6150-0-F