5
ATMOSPHERE REQUIREMENTS
The atmosphere in the ProX 500 SLS installation room must meet the following specifications:
ATMOSPHERIC VARIABLES
Room temperature controls
Temperature
Non-condensing relative humidity
Room air changes
Heat dissipation
Atmospheric corrosives
3D Systems, Inc.
Heating and air conditioning installed
A/C not blowing on top of process station
Operating range: (16 to 27) °C; (60 to 80) °F
Setpoint range: (18 to 24) °C; (65 to 75) °F
Stability: ± 2 °C (± 5 °F)
No higher than 70%
4 per hour minimum
Maximum: 3 .2 kW (11000 BTU/hr)
Average: 2 .4 kW ( 8200 BTU/hr)
None; Clean Dry Air (CDA) is required
17
REQUIREMENTS