MASTER CLAMP & LOADING SECTION
REMOVAL

3. ANGLE SENSOR ASSY.

REMOVAL
1) Pull out the drum, turn off the power and remove the back cover.
2) Before taking off the angular sensor, put a mark in the sensor fitting position so that place for fitting is clearly
known.
3) Disconnect the angular sensor connector, remove fixing screws (× 2) of the angular sensor and take off the
sensor.
- Precaution in Assembly -
• Be sure to use fixing screws of M4 × 6(shorter screw). (A long screw, if used, can hit the drum.)
• Mounting it back to the initial place as referring to the marking, confirm that the angular sensor performs
detection when the clamp plate is closed and opened.
GR3770
Put marking
Pan-head screw SW. W M4 × 6 (× 2)
5 - 8