Riso GR 3770 Technical Manual page 61

Risograph
Table of Contents

Advertisement

Display
T14
Clamp Error (2)
CALL SERVICE
• In 2 seconds from turning ON of the clamp motor in clamp unit
home position return operation, the 0° or 180° angular sensor
has not detected magnet.
• In 2 seconds after the clamp motor gets ON and the 0° or 180°
angular sensor detects magnet in clamp unit home position
return operation, the clamp safety SW has not been pushed.
• In 3 seconds after reverse rotation of the clamp motor in clamp
unit home position return operation, the clamp safety SW has
not been pressed.
* While in master making operation, the master making is per-
formed to the end.
T15
Flat Bed Read Pulse Motor Lock
CALL SERVICE
• If the Image scanner home position sensor does not detect
the Image scanner within 18898 pulses after the Flat bed
read pulse motor is activated.
• If the Image scanner ADF Shading sensor does not detect the
Image scanner within 15748 pulses after the Flat bed read
pulse motor is activated.
• If the Image scanner is not release from the Image scanner
home position sensor within 314 pulses after the Flat bed
read pulse motor is activated.
• If the Image scanner is not released from the Image scanner
ADF Shading sensor within 314 pulses after the Flat bed read
pulse motor is activated.
T15
FB/R Pulse Motor Lock
CALL SERVICE
• In a fixed period of time from turning ON of the Flat bed read
pulse motor, light path of the home position sensor is not blocked.
• In a fixed period of time from turning ON of the Flat bed read
pulse motor, the home position sensor does not become light
receiving state.
• In a fixed period of time from turning ON of the Flat bed read
pulse motor, light path of the ADF shading sensor is not blocked.
• In a fixed period of time from turning ON of the Flat bed read
pulse motor, the ADF shading sensor does not become light
receiving state.
• When Image Scanner Release mode has not been executed.
• When the Image scanner fixing metal has not been removed.
T16
Position C Sensor Malfunction
CALL SERVICE
Displayed to interrupt the machine operation:
• If the Position C sensor status has not been changed from ON
to OFF (or OFF to ON) within 8 seconds from the start of the
Main Motor.
T17
Replace Battery
CALL SERVICE
Displayed to interrupt the machine operation:
REPLACE BATTERY
• If the Battery detection signal is OFF at either of following
three cases.
<1> when the machine power is turned ON <2> when All reset
button is pressed <3> at the end of machine operation.
Details
600dpi type
(300/400dpi type)
(600dpi type)
APX(I)-13
APPENDIX (I)
ADVICE DISPLAYS
How to Cancel
∗ ∗ ∗
Press <ALL RESET> key.
Press <ALL RESET> key.
Press <ALL RESET> key.