5
Main flowchart (2)...Checking VOL YNOFSA D
[From the Main flowchart (1)]
Display RST MASK 21 (Red 1023+). / [MKR S21]
Set VOL YNOFSA D to the tentative setting value 103. / [VYF 103]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
No
Display RST MASK 22 (Green 1023+). / [MKR S22]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
No
Display RST MASK 15 (Magenta 120). / [MKR S15]
Set VOL YNOFSA D to the tentative setting value 151. / [VYF 151]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
No
Return the VOL YNOFSA D to the tentative setting value 128. / [VYF 128]
Determine the tentative setting value for VOL YNOFSA D as the final value.
[Adjustment completed]
Note:
Make sure that the following values become the final setting values.
VOL SUS *1
VOL XPOSF2 *1
VOL OFFSET
VOL YNOFS1 D *1
VOL RST P *1
VOL YNOFS3 D *1
VOL XPOFS1 *1
VOL YNOFS4 D *1
VOL YNOFS4 A
*1: The tentative setting value becomes the final value.
5
6
Yes
To the Recovery flowchart (2-1)
Yes
To the Recovery flowchart (2-2)
Yes
To the Recovery flowchart (2-3)
From the Recovery flowchart (2-2) and (2-3)
KRP-500P
6
7
7
8
A
B
C
D
E
F
131
8