A
[17] QPB (Panel Main Operation Information)
Data on operation of the display main unit can be acquired.
Command
Effective status
Format
[QPB]
Every time
Data Arrangement
B
ECO
Echo back
1
Data on panel temperature
2
Delimiter
3
Unit temperature data 1
4
Delimiter
5
Unit temperature data 2 (reserved)
6
Delimiter
7
Unit temperature data 3 (reserved)
C
8
Delimiter
9
Fan rotation speed A
10
Fan control A/D value (A)
11
Fan rotation speed B
12
Fan control A/D value (B)
13
Room Light Sensor level
14
Room Light Sensor A/D value
15
Dummy 1
D
16
System Operation mode of the panel
17
Dummy 2
18
Audio muting
19
Reserved
CS
Check sum
E
F
90
1
2
Function
To acquire data on current statuses
managed by the Panel Main
microcomputer
Data
Output
Length
Example
3
"QPB"
∗∗∗∗∗
5
Temperature of the panel (in Centigrade) (Tmd)
1
","
Comma
∗∗∗∗∗
5
Temperature inside the unit (in Centigrade) (T1)
1
","
Comma
∗∗∗∗∗
5
Temperature inside the unit (in Centigrade) (T2)
(Reserved, All digits are padded with asterisks.)
1
","
Comma
∗∗∗∗∗
5
Temperature inside the unit (in Centigrade) (T3)
(Reserved, All digits are padded with asterisks.)
1
","
Comma
1
A
Fan setting A (S: stop, L: Low, H: High, and A: Auto)
∗∗∗
3
Fan control D/A value, A, decimal code
1
A
Fan setting B (S: stop, L: Low, H: High, and A: Auto)
∗∗∗
3
Fan control D/A value, B, decimal code
1
5
0-7, padded with an asterisk during the sensor is off
∗∗∗∗
4
Brightness sensor A/D value, decimal code
∗∗
2
All digits are padded with asterisks.
1
S
S: System Operation mode, T: Standalone Operation mode
∗∗
2
All digits are padded with asterisks.
1
0
0: Canceling muting, 1: Muting
∗∗
10
All digits are padded with asterisks.
2
(CS)
KRP-500P
2
3
Remarks
Return data: 3 (ECO) + 53 (DATA) + 2 (CS) = 58 Byte