5
Command
P
PGG
S08
Green gamma setting: Fixed at 2.3
S09
Green gamma setting: Fixed at 2.4
S10-31 Green gamma setting: Customized
PGH
***
Panel white balance adjustment-Green high-light
PGL
***
Panel white balance adjustment-Green low-light
PGX
***
Panel Gx measurement value
PGY
***
Panel GY measurement value
PGR
S00
Red gamma setting: Straight
S01
Red gamma setting: Fixed at 1.6
S02
Red gamma setting: Fixed at 1.7
S03
Red gamma setting: Fixed at 1.8
S04
Red gamma setting: Fixed at 1.9
S05
Red gamma setting: Fixed at 2.0
S06
Red gamma setting: Fixed at 2.1
S07
Red gamma setting: Fixed at 2.2
S08
Red gamma setting: Fixed at 2.3
S09
Red gamma setting: Fixed at 2.4
S10-31 Red gamma setting: Customized
PKD
S00
Peak Brightness Detection: OFF
S01
Peak Brightness Detection: ON
PKL
S00
No brightness limitation: 100%
S01
Brightness limitation1: 87%
S02
Brightness limitation2: 73%
S03
Brightness limitation3: 60%
S04
Brightness limitation4: 52%
S05
Brightness limitation5: 40%
S06
Brightness limitation6: 27%
S07
Brightness limitation7: 13%
PMT
S00
To cancel panel muting
S01
Panel muting
POF
To turn the unit OFF
PON
To turn the unit ON
PPT
S00
Panel Protection function: OFF
S01
Panel Protection function: ON
PRH
***
Panel white balance adjustment-Red high-light
PRL
***
Panel white balance adjustment-Red low-light
PRX
***
Panel Rx measurement value
PRY
***
Panel Ry measurement value
Q
QAJ
To acquire various adjustment values
QAL
To acquire the NG (SD) history managed by the Panel Main microcomputer
QPB
To acquire various data managed by the Panel Main microcomputer
QPD
To acquire the history of power-down places
QPM
To acquire pulse-meter data
QPW
To acquire white balance adjustment data of the panel
QPF
To acquire characteristics/function settings data of the panel
QS1
To acquire panel information, such as software versions
QS2
To acquire panel status data, such as acquired temperatures
of the panel in cases of operation changes
QS3
To acquire panel information other than the above
QS5
To acquire panel information (Individual functions)
QSB
To acquire versions of various microcomputers of the panel main unit
QSP
To acquire subversions of various microcomputers of the panel
QSD
To acquire shutdown data
QSI
To acquire signal-related data
5
6
Command
Receiving UCOM
Function
MOD
KRP-500P
6
7
Effective only
Last
Memory
during FAY
PM
MOD
MOD
MOD
MOD
Muting cannot be performed while the built-in mask
signal output is being displayed.
PM
PM
MOD
MOD
MOD
MOD
7
8
A
Remarks
B
C
D
E
F