Pioneer KRP-500P Service Manual page 108

Hide thumbs Also See for KRP-500P:
Table of Contents

Advertisement

1
A
[2-6] PANEL MAIN BEZEL SETUP
Setup of the bezel can be performed on the PANEL MAIN BEZEL SETUP screen.
• Without the Panel Main Bezel setup, detection by the Room Light Sensor will not be performed properly.
• Even if Final setup (in System Operation mode [FSTS35] or in Display Standalone Operation mode [FSP]) is performed,
the initial value (R1) will not be restored.
1
5
1
P
M
F
A
C
T
O R Y
P M
S E T U P
5
B
10
P M
B E Z E L
15
16
Select the bezel setup setting, using the L or R key, then press the SET key to determine the setting.
When NO OPT is selected, bezel setup is not performed.
C
Each time the L or R key is pressed, setup settings are changed, as shown below:
R1
R2
R3
"NO OPT" is selected immediately after the PANEL MAIN BEZEL SETUP screen is displayed.
R1: The bezel setup is performed according to ROM table 01. (Default)
R2: The bezel setup is performed according to ROM table 02.
R3: The bezel setup is performed according to ROM table 03.
EP: The bezel setup is performed according to the EEPROM table. (For use by engineers)
NO OPT: Bezel setup is not performed.
D
[2-7] PANEL MAIN NG CLEAR
The shutdown logs can be cleared on the PM NG CLEAR screen.
1
5
1
P
M
F
A
C
T
O R Y
P M
S E T U P
5
E
10
P M
N G
C L E A R
15
16
"NG CLEAR" denotes clearing of the SD logs managed by the Panel Main microcomputer.
Select the setting, using the L or R key, then press the ENTER/SET key to clear the data.
When NO OPT is selected, NG CLEAR is not performed.
F
Pressing the L or R key toggles between CLEAR and NO OPT, as shown below:
CLEAR
NO OPT
108
1
2
10
15
20
25
I
N 1
3
0 1 0
1
– N T V
S E T U P
< = >
R 1
EP
NO OPT
10
15
20
25
I
N 1
3
0 1 0
1
– N T V
< = >
C L E A R
2
3
30
32
g Key operation
J
H
B
<DOWN> : Shifting to the next item
<UP>
: Shifting to the previous item
<RIGHT> : Changing the setting value upward (+)
<LEFT>
: Changing the setting value upward (-)
<ENTER/SET> : Determining the changed value
30
32
g Key operation
J
H
B
<DOWN> : Shifting to the next item
<UP>
: Shifting to the previous item
<RIGHT> : Changing the setting value upward (+)
<LEFT>
: Changing the setting value upward (-)
<ENTER/SET> : Determining the changed value
KRP-500P
3
4
and return to the layer above
and return to the layer above
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents