Execution Condition For Manual Regeneration - Kubota D1803-CR-E4 Workshop Manual

Wsm
Hide thumbs Also See for D1803-CR-E4:
Table of Contents

Advertisement

DIESEL PARTICULATE FILTER HANDLING MANUAL, WSM

[13] EXECUTION CONDITION FOR MANUAL REGENERATION

To execute manual regeneration, it is required to set the following conditions.
(1) Parking break on
(2) Transmission in neutral
(3) Implement down
Step3
1. Execute the request by the "DPF Manual Regeneration
Request Function" in the utility functions of the diagnosis tool,
and give the command to execute on the application side.
(When the execution button is not on the application side, ECU
on the application side receives the request signal and gives
command to execute.)
Step4
1. Check if the "DPF Regeneration Control Level" and the "DPF
Regeneration Control Status" shows "Level 0" by the monitor
functions in the diagnosis tool.
If the level is 0, it means that manual regeneration has
completed.
1-S38
ENGINE
KiSC issued 09, 2013 A