Parameter
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature
regime (**)
Useful efficiency
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature
regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency
Daily electricity consumption
Daily fuel consumption
Annual electricity consumption
Annual fuel consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return
temperature (at heater inlet).
Symbol
C.A.I. 24kW
-
C
-
B
Pnominal
24
ηs
77
P4
24,0
P1
7,1
η4
80,9
η1
80,3
elmax
17,0
elmin
7,2
PSB
3,0
Pstby
135,0
Pign
-
QHE
90
LWA
54
NOx
143
XL
ηwh
78
Qelec
0,124
Qfuel
25,526
AEC
27
AFC
19
9
Exclusive C.A.I.
C.A.I. 28kW
Unit
C
B
29
kW
77
%
28,7
kW
8,5
kW
81,0
%
80,3
%
14,0
W
6,3
W
3,0
W
141,0
W
-
W
107
GJ
53
dB
143
mg/ kWh
XL
78
%
0,125
kWh
25,647
kWh
27
kWh
19
GJ
-
-