Programming principles
1.11 Subroutine technique
Subroutine call
Subroutines are called in a program (main or subprogram) with their names. To do this, a
separate block is required.
Example:
N10 L785
N20 SHAFT7
Program repetition P...
If a subroutine is to be executed several times in succession, write the number of times it is
to be executed in the block of the call after the subroutine name under the address P. A
maximum of 9,999 cycles are possible (P1 ... P9999).
Example:
N10 L785 P3
Nesting depth
Subroutines can also be called from a subroutine, not only from a main program. In total, up
to 8 program levels are available for this type of nested call, including the main program
level.
Figure 1-52
Information
Modal G functions can be changed in the subroutine, e.g. G90 -> G91. When returning to the
calling program, ensure that all modal functions are set the way you need them to be.
Please make sure that the values of your arithmetic parameters used in upper program
levels are not inadvertently changed in lower program levels.
When working with SIEMENS cycles, up to 7 program levels are needed.
96
; Subprogram call L785
; Subprogram call SHAFT7
; Subprogram call L785, 3 cycles
Execution with 8 program levels
Turning Part 2: Programming (Siemens instructions)
Programming and Operating Manual, 05/2012, 6FC5398-5DP10-0BA0