Siemens sinumerik 808d Programming And Operating Manual page 143

Hide thumbs Also See for sinumerik 808d:
Table of Contents

Advertisement

Explanation of the parameters
For an explanation of the parameters RTP, RFP, SDIS, DP, and DPR, refer to the topic
"Drilling, centering - CYCLE81 (Page 112)".
DTB (dwell time)
The dwell time to the final drilling depth (chip breakage) is programmed under DTB in
seconds.
Programming example: Fifth boring
At X0, the CYCLE89 drilling cycle is called with a safety clearance of 5 mm and specification
of the final drilling depth as an absolute value. The drilling axis is the Z axis.
N10 G90 G17 F100 S450 M4
N20 G0 X0 Z107
N30 CYCLE89(107, 102, 5, 72, ,3)
N40 M2
Turning Part 2: Programming (Siemens instructions)
Programming and Operating Manual, 05/2012, 6FC5398-5DP10-0BA0
2.4 Drilling cycles
; Specification of technology
values
;Approach drilling position
; Cycle call
; End of program
Cycles
143

Advertisement

Table of Contents
loading