Introduction; General Information; Product Information; Revision History - Daikin MicroTech III Installation And Operation Manual

Unit controller remote user interface
Hide thumbs Also See for MicroTech III:
Table of Contents

Advertisement

General Information

This manual contains the information needed to install and
operate the remote user interface for use with MicroTech
Applied Air and Air-Cooled Scroll Chiller unit controllers from
Daikin Applied.
For technical support on rooftop or self-contained unit
controllers, contact the Daikin Applied Air Technical Response
Center at 844-521-3928 (techresponseaah@daikinapplied.com).
For chiller unit controller support, contact the Daikin Applied
Chiller Technical Response Center at 540-248-9239
(techresponse@daikinapplied.com).

Product Information

The remote user interface is designed for display, system
configuration, set-up, and management of MicroTech III unit
controllers:
• Roofpak
®
Applied Packaged Rooftops
• Self-Contained Air Conditioning Systems
• Rebel
and Maverick
®
®
• Pathfinder
and Trailblazer
®
In addition to the unit-mounted controller keypad/display,
MicroTech III unit control systems can be equipped with
a remote user interface that handles up to eight units per
interface. The remote user interface provides access to unit
diagnostics and control adjustments similar to the unit-mounted
controller.

Revision History

IM 1005
January 2010
IM 1005-1
September
2010
IM 1005-2
March 2012
IM 1005-3
November 2016

Notice

© 2016 Daikin Applied, Minneapolis MN. All rights reserved
throughout the world
Daikin Applied reserves the right to change any information
contained herein without prior notice. The user is responsible
for determining whether this product is appropriate for his or
her application.

Limited Warranty

™ ® The following are trademarks or registered trademarks
of their respective companies: Daikin Applied, Trailblazer,
Pathfinder, Maverick, Rebel, Roofpak and MicroTech III
from Daikin Applied. Consult your local Daikin Applied
www.DaikinApplied.com
II Commercial Packaged Rooftops
Air-Cooled Chillers
®
Initial release
Added Daikin Trailblazer
chiller model
®
AGZ-D
Added Rebel
®
packaged rooftop model
DPS. Updated Figure 3 with labels and
connector cables.
Added models AWV Pathfinder
®
chiller and AGZ-E Trailblazer
chiller,
®
added RJ45 direct connection option,
corrected bus wiring distance limitations,
Troubleshooting section, Daikin
branding and formatting updates
representative for warranty details. To find your local Daikin
III
Applied representative, go to www.DaikinApplied.com.
®
Hazardous Information Messages
Recognize Safety Symbols, Words and Labels
The following symbols and labels are used throughout this
manual to indicate immediate or potential hazards. It is the
owner and installer's responsibility to read and comply with
all safety information and instructions accompanying these
symbols. Failure to heed safety information increases the
risk of property damage and/or product damage, serious
personal injury or death. Improper installation, operation and
maintenance can void the warranty.
Cautions indicate potentially hazardous situations, which can
result in personal injury or equipment damage if not avoided.
Static sensitive components. Can cause equipment damage.
Discharge any static electrical charge by touching the bare
metal inside the control panel before performing any service
work. Never unplug cables, circuit board terminal blocks, or
power plugs while power is applied to the panel
Warnings indicate potentially hazardous situations, which can
result in property damage, severe personal injury, or death if
not avoided.
Dangers indicate a hazardous situation which will result in
death or serious injury if not avoided. Electric shock hazard.
Can cause personal injury or equipment damage. This
equipment must be properly grounded. Connections and
service to the MicroTech III unit controller must be performed
only by personnel knowledgeable in the operation of the
equipment being controlled.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with this instruction manual, may cause interference to radio
communications. It has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment
is operated in a commercial environment. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct
the interference at his or her own expense. Daikin disclaims
any liability resulting from any interference or for the correction
thereof.
3
IM 1005-3 • MICROTECH III REMOTE USER INTERFACE

Introduction

CAUTION
WARNING
DANGER
NOTICE
Introduction

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents