Check

4.1.11 Hall IC Check

Check No.16
1. Check the connector connection.
2. With the power on, operation off, and the connector connected, check the following.
If NG in step 1 Æ Defective PCB Æ Replace the PCB.
If NG in step 2 Æ Defective Hall IC Æ Replace the fan motor.
If OK in both steps 1 and 2 Æ Replace the PCB.
The connector has 3 pins.

4.1.12 Main Circuit Short Check

Check No.29
Note:
Check to make sure that the voltage between (+) and (–) of the diode bridge (DB1) is approx.
0 V before checking.
„ Measure the resistance between the pins of the DB1 as below.
„ If the resistance is ∞ or less than 1 kΩ, short circuit occurs on the main circuit.
(–) terminal of the tester
(in case of digital,
(+) terminal)
(+) terminal of the tester
(in case of digital,
(–) terminal)
Resistance in OK
Resistance in NG
RK(X)S25/35E2V1B models
110
∗Output voltage of about 5 V between pins 1 and 3.
∗Generation of 3 pulses between pins 2 and 3 when the fan motor is operating.
1
2
3
~ several MΩ
1
2
3
4
– ~ ~ +
Tester
Gray (power supply)
Purple (signals)
Blue (grounding)
~
+
(2, 3)
(4)
+
~
(4)
(2, 3)
several kΩ
0 Ω or
0
SiENBE05-722_A
(R1990)
~
(1)
(2, 3)
~
(1)
(2, 3)
several kΩ
~ several MΩ
0 Ω or
0
(R12412)