technical data

FLKS-BAVMB
Flexi Type,
Inverter Controlled Unit
Split
Sky Air

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLKS25BAVMB and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FLKS25BAVMB

  • Page 1: Technical Data

    technical data FLKS-BAVMB Flexi Type, Inverter Controlled Unit Split Sky Air...
  • Page 2: Table Of Contents

    • Indoor Units • R410A • FLKS-BAVMB TABLE OF CONTENTS FLKS-BAVMB Features ............. 2 Specifications .
  • Page 3: Features

    • Auto-swing function ensures efficient air and temperature distribution. • Daikin remote controls give you easy control at your fingertips. • Air purification filter: deodorises the air and helps to prevent bacterial • The remote control has a 24-hour timer and viral propagation •...
  • Page 4: Specifications

    • Indoor Units • R410A • FLKS-BAVMB Specifications 2-1 FOR INDOOR UNITS ONLY FLKS25BAVMB FLKS35BAVMB FLKS50BAVMB FLKS60BAVMB Nominal Input Cooling 0.074 0.078 0.096 0.098 2-2 TECHNICAL SPECIFICATIONS FLKS25BAVMB FLKS35BAVMB FLKS50BAVMB FLKS60BAVMB Casing Colour Almond white Dimensions Packing Height Width 1100...
  • Page 5: Electrical Specifications

    • Indoor Units • R410A • FLKS-BAVMB Specifications 2-2 TECHNICAL SPECIFICATIONS FLKS25BAVMB FLKS35BAVMB FLKS50BAVMB FLKS60BAVMB Standard Item Installation and operation manual Accessories Quantity Item Infrared remote control Quantity Item Batteries Quantity Item Remote control holder Quantity Item Air purification filter...
  • Page 6: Options

    Anti-theft protection for remote control KKF917AA4 (1) Wiring adapter is also required for each indoor unit. (2) Wiring adapter supplied by Daikin. Time clock and other devices: field supply. (3) For DIII-NET adapter • Split Sky Air • Indoor Units...
  • Page 7: Control Systems

    • Indoor Units • R410A • FLKS-BAVMB Control systems FLK/XS -B <ARC433A5, A6> Signal transmitter: OUTDOOR UNIT SILENT button: • It sends signals to the indoor unit. SILENT operation Display: FAN setting button: • It displays the current settings. (In this illustration, each •...
  • Page 8: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • R410A • FLKS-BAVMB Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing unit (mm) FLK/XS25-35-50-60B Floor level installation Required space Air flow (indoor) The mark (Y) shows piping direction (for performance and maintenance) Rear (space for (space for maintenance)
  • Page 9: Centre Of Gravity

    • Indoor Units • R410A • FLKS-BAVMB Dimensional drawing & centre of gravity 5 - 2 Centre of gravity FLK/XS-B 4D027653C • Split Sky Air • Indoor Units...
  • Page 10: Piping Diagram

    • Indoor Units • R410A • FLKS-BAVMB Piping diagram FLK/XS25-35-50-60B Indoor unit FLX(K)S25B J 9.5 J 9.5 J 6.4 FLX(K)S35B FLX(K)S50B J 12.7 J 12.7 J 9.5 FLX(K)S60B Heat exchanger Thermistor on heat exchanger Field piping Sirocco fan (6.4Cut) Field piping Fan motor (ACut) Refrigerant flow...
  • Page 11: Wiring Diagram

    • Indoor Units • R410A • FLKS-BAVMB Wiring diagram 7 - 1 Wiring diagram FLK/XS25-35-50-60B Caution: Notice that operation will restart automatically when the main power supply is turned off and then turned on again. Outdoor Transmission circuit Field wiring Signal receiver Indoor : Running capacitor...
  • Page 12: Sound Data

    • Indoor Units • R410A • FLKS-BAVMB Sound data 8 - 1 Sound level data Cooling only Sound pressure level 230V, 50Hz Sound power level Model (Cooling) Cooling Measuring location Location of microphone FLKS25B FLKS35B FLKS50B FLKS60B Heat pump Sound pressure level 230V, 50Hz Sound power level Model...
  • Page 13: Sound Pressure Spectrum

    • Indoor Units • R410A • FLKS-BAVMB Sound data 8 - 2 Sound pressure spectrum FLKS35B FLKS25B approximate threshold approximate threshold hearing for continuous hearing for continuous noise noise 4D035260A Octave band center frequency (Hz) 4D035261A Octave band center frequency (Hz) NOTE NOTE Operation noise differs with operation and ambient...
  • Page 14: Installation

    • Indoor Units • R410A • FLKS-BAVMB Installation 9 - 1 Installation method There should be no space between Space for installation work. Min. ceiling and the unit. (200mm) Space for installation work. Min. (200mm) Air filters 50 mm or more from walls (on Mounting plate both side) The mounting plate...
  • Page 15 • Indoor Units • R410A • FLKS-BAVMB Installation 9 - 1 Installation method Ceiling mounting Rear side piping hole J65 mm Local drain pipe Ceiling Ceiling Wall *1 Determine the position of the feed-through hole so that the local piping is placed in a Rear side drain hose hole J40 mm downward sloping direction.
  • Page 16 Daikin Europe N.V. explicitly rejects any liability for any direct Daikin Europe N.V. is approved by LRQA for its Quality Daikin Europe N.V. is participating in the or indirect damage, In the broadest sense, arising from Management System in accordance with the ISO9001 EUROVENT Certification Programme.