Outdoor Unit - RK(X)S25/35G2V1B9
4.4

Removal of Reactor / Partition Plate

Procedure
Step
1. Remove the reactor.
1
Remove the screw and
remove the reactor.
2. Remove the partition
plate.
1
Remove the 2 screws.
198
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Reactor
(R11879)
(R11880)
Partition plate
(R12273)
SiENBE05-722_A
Points
Preparation
„ Remove the outer panels
according to the "Removal of
Outer Panels / Fan Motor".
„ Remove the electrical box
according to the "Removal of
Electrical Box".
Removal Procedure